3-240
Performance Tests
Performance Test Record
Pulse Amplitude Ratio
0.95
1.05
Pulse Width Ratio
0.95
1.05
Unbal 34 Mb/s
Min
Actual
Max
3-17
Step 34:
+ve Pulse Amp
0.900 V pk
1.100 V pk
+ve Pulse Mask
Pass/Fail
-ve Pulse Amp
0.900 V pk
1.100 V pk
-ve Pulse Mask
Pass/Fail
Pulse Amplitude Ratio
0.95
1.05
Pulse Width Ratio
0.95
1.05
Unbal 140 Mb/s
(All Ones)
3-19
Step 39:
+ve Pulse Amp
0.900 V pk
1.100 V pk
Step 40:
+ve Pulse Mask
Pass/Fail
Unbal 140 Mb/s
(All Zeros)
3-20
Step 44:
-ve Pulse Amp
0.900 V pk
1.100 V pk
Step 45:
-ve Pulse Mask
Pass/Fail
PDH Multiple TX Outputs
704 kb/s Out 2
(UKK only)
3-24
Step 6:
+ve Pulse Amp
2.133 V pk
2.607 V pk
+ve Pulse Width
639 ns
781 ns
Overshoot
0.474 V
Undershoot
0.474 V
704 kb/s Out 3
(UKK only)
Step 7:
+ve Pulse Amp
2.133 V pk
2.607 V pk
Table 11
Performance Test Record
Page
No.
Test Description
Result
Min Actual Max
Summary of Contents for 37717C
Page 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Page 5: ...2 ...
Page 21: ...xviii Contents ...
Page 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Page 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Page 375: ...3 266 Performance Tests Performance Test Record ...
Page 379: ...4 4 Installation Current Previous Terminology ...
Page 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Page 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...