3-104
Performance Tests
STM-1/STM-4, 1550nm Optical Interface (Option URU)
STM-1/STM-4, 1550nm Optical Interface (Option URU)
N OT E
An SDH Option must be fitted for this option to operate - see Appendix B.
Specification (Transmitter)
Specification (Receiver)
Description
Minimum and maximum Optical Rx Input levels are verified by looping the Optical
Tx and Rx ports through the Optical Attenuator and checking for error-free
operation with identical Tx and Rx patterns selected. The signal level to the Optical
Rx input is measured using the Power Meter and adjusted using the Optical
Attenuator for the required minimum and maximum levels.
Wavelength
1520 nm to 1565 nm
Power Output
-1 dBm (Nominal)
Line Coding
NRZ
Safety Class
Class 1, FDA 21 CFR Ch.1 1040.10 and EN 60825
Data Rate
155.52 Mb/s or 622.08 Mb/s (Nominal)
Wavelength
1200 nm to 1600 nm
Maximum Input Power
-8 dBm (for BER of 1.0E
-10
)
Line Coding
NRZ
Sensitivity
-26 dBm Minimum (wavelength=1550nm,
Modulation=100%,Data=2
23
-1, BER=1.0E
-10
)
PMP Electrical Input
150mV (Nominal)
PMP Impedance
Nominal 50
Ω
Summary of Contents for 37717C
Page 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Page 5: ...2 ...
Page 21: ...xviii Contents ...
Page 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Page 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Page 375: ...3 266 Performance Tests Performance Test Record ...
Page 379: ...4 4 Installation Current Previous Terminology ...
Page 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Page 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...