3-50
Performance Tests
SPDH Receiver Monitor Levels (Options UKJ, [USA], UKL, [USC], UKN,
[USE])
SPDH Receiver Monitor Levels (Options UKJ, [USA],
UKL, [USC], UKN, [USE])
N OT E
An SPDH Tx Module must be fitted for this test - see Appendix B.
Specifications
Description
The signal from the HP 37717C PDH Transmitter is applied to the PDH Receiver
after attenuating by an amount equal to the selected Receiver Flat Loss plus the
specified Cable Loss. The Flat Loss is obtained by inserting a number of 50
Ω
, fixed
attenuators in series with a 75/50
Ω
Matching Pad at one end and a 50/75
Ω
Matching Pad at the other end. The loss of the two Matching Pads is included in the
overall attenuation equation. The Cable Loss is supplied by inserting the correct
Cable Simulators for each bit rate in the attenuation path.
Equipment Required
Bit Rate
Nominal Loss
Equalization at 1/2 Bit Rate
2.048 Mb/s
20, 26, 30dB
3dB
8.448 Mb/s
20, 26, 30dB
3dB
34.368 Mb/s
20, 26dB
6dB
139.264 Mb/s
20, 26dB
6dB
Table 3- 2
Cable Simulator #1
: 80 metres (262 ft) of 75
Ω
coaxial cable (8120-0049)
Cable Simulator #2
: 60 metres (197 ft) of 75
Ω
coaxial cable (8120-0049)
Cable Simulator #3
: 70 metres (230 ft) of 75
Ω
coaxial cable (8120-0049)
Cable Simulator #4
: 30 metres (98 ft) of 75
Ω
coaxial cable (8120-0049)
Summary of Contents for 37717C
Page 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Page 5: ...2 ...
Page 21: ...xviii Contents ...
Page 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Page 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Page 375: ...3 266 Performance Tests Performance Test Record ...
Page 379: ...4 4 Installation Current Previous Terminology ...
Page 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Page 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...