3-148
Performance Tests
Transmitted Jitter/Wander Amplitude Accuracy (Option A3K [A3Q])
5. Select
and setup the
Reference HP 37717C display as shown
opposite.
6. Select
and setup
the Reference HP 37717C display as shown
opposite.
7. Select
and setup the
Reference HP 37717C display as shown
opposite.
8. Press
and check that at the
end of the measurement period (10
seconds) the
display PEAK-PEAK result is
80.000 BITS
±
5.5 BITS.
9. Disconnect all the test equipment.
RECEIVE
PDH
RECEIVE
JITTER
RESULTS
TIMING CONTROL
RUN/STOP
RESULTS
WANDER
WANDER
Summary of Contents for 37717C
Page 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Page 5: ...2 ...
Page 21: ...xviii Contents ...
Page 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Page 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Page 375: ...3 266 Performance Tests Performance Test Record ...
Page 379: ...4 4 Installation Current Previous Terminology ...
Page 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Page 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...