3-109
Performance Tests
STM-1/STM-4 Optical Interface (Options UKT, USN)
STM-1/STM-4 Optical Interface (Options UKT, USN)
N OT E
An SDH Option must be fitted for this option to operate - see Appendix B.
Specification (Transmitter)
Specification (Receiver)
Description
The 155.52/622.08 MHz output of the optical transmitter is checked for power level
at 1310 nm (and 1550 nm wavelengths if Option USN). The receiver sensitivity is
verified by attenuating the transmitter output and checking for no errors in back-to-
Wavelength
UKT - 1280 nm to 1330 nm,
USN - 1280 nm to 1330 nm or 1520 nm to 1565 nm
Power Output
1310 nm -10 dBm (Nominal).
1550 nm -1dBm (Nominal)
Line Coding
NRZ
Safety Class
Class 3A, FDA 21 CFR Ch.1 1040.10 and EN 60825
Data Rate
155.52 Mb/s or 622.08 Mb/s (Nominal)
Wavelength
1200 nm to 1600 nm
Maximum Input Power
-8 dBm (for BER of 1.0E
-10
)
Line Coding
NRZ
Sensitivity
-34 dBm Minimum (STM-1),
- 28 dBm Minimum (STM-4)
(wavelength=1300nm, Modulation=100%,
Data=2
23
-1, BER=1.0E
-10
)
PMP Input
150mV pk-pk minimum
PMP Impedance
Nominal 50
Ω
Summary of Contents for 37717C
Page 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Page 5: ...2 ...
Page 21: ...xviii Contents ...
Page 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Page 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Page 375: ...3 266 Performance Tests Performance Test Record ...
Page 379: ...4 4 Installation Current Previous Terminology ...
Page 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Page 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...