3-39
Performance Tests
PDH Frame Analysis (Options UKK, [USB])
8 Mb/s Frame Analysis
1. Select SIGNAL [8 Mb/s] on the HP 37717C
display then return to
Display.
2. Set the HP 37729A Frame Generator parameters as follows:
OUTPUT: FREQ [8]; CODE [HDB3]
ALIGNMENT [8M]
SB [00]
FAS [1111010000]
Press the
key until all 8448 Kbit/s ERROR and AIS Led’s are OFF.
3. Press
on the HP 37717C to start a measurement and check that all
Alarm Led’s are OFF on the HP 37717C. The Error Count and Error Ratio should be
0.
Error Detection
4. Use the Frame Generator 8448 Kbit/s
and
keys to select and
enable BIT ERROR.
5. Check that HP 37717C Errors and Remote alarm Led’s are ON (may be flashing).
6. Check that the HP 37717C counts Frame (FAS) Errors. The Code Error count
should be 0.
7. Press the Frame Generator 8448 Kbit/s
key and check that the FRAME
(FAS) Error Count is 0 and all Alarm Led’s are now OFF.
Alarm Detection
8. Set the Frame Generator SB parameter to [10].
9. Check that the HP 37717C Remote Alarm Led is ON. Error Count and Error
Ratio should be 0.
10. Reset the Frame Generator SB parameter to [00].
FAS Error and AIS
11. Use the Frame Generator 8448 Kbit/s
and
keys to select and
enable FAS ERROR.
12. Check that the HP 37717C Frame Loss alarm Led is ON.
13. Press the Frame Generator 8448 Kbit/s
key and check that the FRAME
(FAS) Error Count is 0 and all Alarm Led’s are now OFF.
RECEIVE
RESULTS
SELECT
RUN/STOP
SELECT
ON/OFF
ON/OFF
SELECT
ON/OFF
ON/OFF
Summary of Contents for 37717C
Page 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Page 5: ...2 ...
Page 21: ...xviii Contents ...
Page 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Page 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Page 375: ...3 266 Performance Tests Performance Test Record ...
Page 379: ...4 4 Installation Current Previous Terminology ...
Page 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Page 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...