3-157
Performance Tests
Wander/Slips Measurement (Options UHN, [US9], A1M [A1Q], A1N
[A1R], A1P [A1S], A3L [A3M], A3V [A3W], A3N [A3P])
16. Select
TEST TIMING [SINGLE] [60 SECS].
17. Press
and set up the
Display as shown opposite.
18. Set both Synthesizers amplitude to
10dBm.
19. Set the Synthesizer connected to PDH
IN to generate a sinewave at 1,024,094.4Hz
and the Synthesizer connected to the
TIMING REF INPUT to generate a
sinewave at 2,048,204.8Hz.
20. Press
and verify that the Display shows the following at the end of
the test period:
21. Select RESULTS [WANDER] [WANDER] and verify that the display shows the
following:
NOTE: In some cases the above two sets of results will all be on the same display.
22. Select RESULTS [WANDER] [BIT SLIPS].
23. Set The Synthesizer connected to PDH IN to generate 1,023,889.6Hz and the
Synthesizer connected to the TIMING REF INPUT to generate 2,047,795.2Hz and
repeat steps 19 to 21.
24. Set The Synthesizer connected to PDH IN to generate 1,023,905.6 Hz.
RESULTS
TIMING CONTROL
RESULTS
RUN/STOP
ESTIMATED BIT SLIPS
: -955 TO -964 BITS
ESTIMATED FRAME SLIPS
: -3 to -4
POSITIVE PEAK
0.000 BITS
NEGATIVE PEAK
955.125 to 964.875 BITS
PEAK TO PEAK
955.125 to 964.875 BITS
PEAK TO PEAK 15 MINUTES
.…BITS
PEAK TO PEAK 24 HOURS
.…BITS
TIME INTERVAL ERROR
-955.125 to -964.875 BITS
Summary of Contents for 37717C
Page 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Page 5: ...2 ...
Page 21: ...xviii Contents ...
Page 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Page 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Page 375: ...3 266 Performance Tests Performance Test Record ...
Page 379: ...4 4 Installation Current Previous Terminology ...
Page 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Page 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...