3-108
Performance Tests
STM-1/STM-4, 1550nm Optical Interface (Option URU)
28. Connect the output from the Optical /Electrical Converter to the Oscilloscope
using the SMA/BNC adaptor and 50
Ω
BNC cable.
29. Set the Dual Power Supply to +12V and -12V, then connect to the HP 83442A O/
E Converter and switch on.
C AU T I O N
Take care to connect the supply correctly as incorrect voltage or polarity could result
in damage to the HP 83442A. Refer to HP 83442A Operating Instructions, HP p/n
5091-6448A.
30. Press
on the HP 37717C and select SIGNAL [STM-4 OPT].
31. Press
on the oscilloscope and adjust the Timebase and Range to
obtain an STM-4 waveform.
32. Measure the amplitude of this STM-4 waveform using the oscilloscope and adjust
the Optical Attenuator until the amplitude is 150mV.
N OT E
If the input power is greater than -8 dBm then the Optical/Electrical converter is liable
to saturate.
33. Disconnect the output of the O/E Converter from the oscilloscope and connect
instead to the HP 37717C STM1/4 Optical Module Monitor Input.
34. Press
on the HP 37717C
and set up the display as shown opposite.
35. Press
then
to start the measurement.
36. After 5 minutes, check that NO
TROUBLE is displayed on the HP 37717C
display.Press
to
stop the measurement.
37. Recall the HP 37717C DEFAULT
SETTINGS as shown on 3-2.
38. Verify that the Optical Module LASER ON led is NOT lit indicating that the laser
is disabled before continuing.
39. Repeat steps 1 to 38 but with [STM-1 OPT] selected on the HP 37717C Tx and
Rx display parameters instead of [STM-4 OPT].
40. Disconnect all Test equipment.
TRANSMIT
SDH
AUTOSCALE
RECEIVE
RESULTS
TROUBLE SCAN
RUN/STOP
RESULTS
RUN/STOP
Summary of Contents for 37717C
Page 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Page 5: ...2 ...
Page 21: ...xviii Contents ...
Page 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Page 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Page 375: ...3 266 Performance Tests Performance Test Record ...
Page 379: ...4 4 Installation Current Previous Terminology ...
Page 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Page 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...