Installation Instructions for the
FF-SRS5939
Interface Control Module
for Safety Light Curtains
PK 107033-EN
(pending)
107033-12 EN FR26 GLO 0499 Printed in Germany
IMPROPER INSTALLATION
•
Consult with US and/or European safety agencies
and their requirements when designing a machine
control, interface and all control elements that
affect safety.
•
The FF-SRS5939 interface control module is
designed to be used with Honeywell
electrosensitive protective equipment using fail-
safe solid state outputs. These equipment perform
cross-fault detection between their outputs. The
FF-SRS5939 module does not perform the cross-
fault detection between its inputs. To ensure the
highest safety category, do NOT use the FF-
SRS5939 with any other equipment. For
electrosensitive protective equipment equiped with
relay outputs, use the FF-SRS5935 or FF-
SRS5925 dual channel emergency stop module,
and for the electromechanical safety switches,
use the FF-SRD5985 door monitoring module.
These three modules perform the cross-fault
detection between their inputs.
•
Strictly adhere to all installation instructions.
Failure to comply with these instructions could
result in death or serious injury.
PRODUCT DESCRIPTION
The FF-SRS5939 interface control module is
designed to be used in emergency stop circuits
when danger to personnel or machinery is present.
This device has two internal safety relays with
positive-guided contacts to ensure redundancy.
This safety module provides an emergency stop
signal to the machine control circuitry. FF-SRS5939
helps to create a control reliable safety solution by
providing redundancy and self-checking circuitry.
Other features include high current capability, an
automatic start and manual start mode and external
relays monitoring.
APPROVALS
CE
The product, packaging and
documentation of FF-SR Series
products is pending CE mark
following an examination by BG
(
German Berufsgenossenschaft
E+MIII)
cULus
(pending)
This product is pending approval
by Underwriters Laboratories Inc.
according to Canadian and U.S.
safety requirements.
DIRECTIVES COMPLIANCE
Machine Directive 98/37/EEC
Low Voltage Directive 73/23 EEC
Electromagnetic Compatibility Directive 89/336
REGULATIONS COMPLIANCE
Regulation
Title
OSHA 29 CFR
1910.212
General Requirements for
(guarding of) All Machines
OSHA 29 CFR
1910.217
(Guarding of) Mechanical
Power Presses
STANDARDS COMPLIANCE
Standard
Title
EN 292
Safety of Machinery - Basic
Concepts, General Principles
for Design
EN 60204 - 1
Safety of Machinery -
Electrical Equipment of
Machines
EN 954 - 1
Safety of Machinery - Safety
related parts of control
system
EN 61496 - 1
Safety of Machinery-
ElectroSensitive Protective
Equipment.
UL508
Underwriters Laboratories
ANSI B11.1
Mechanical Power Presses
ANSI B11.2
Hydraulic Power Presses
ANSI B11.19
Safeguarding when
Referenced by the Other
B11 Machine Tool Safety
Standards
ANSI/RIA R15.06
Safety Requirements for
Industrial Robots and Robot
Systems
Summary of Contents for SYA14 Series
Page 2: ...2 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 6: ...6 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 26: ...26 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 62: ...62 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 70: ...70 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 76: ...76 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 78: ...78 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 79: ...107031 23 EN FR26 GLO 1199 Printed in France 79 8 CE Declaration of Conformity ...
Page 80: ...80 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 84: ......
Page 158: ......
Page 160: ......
Page 161: ...For application help call 1 800 537 6945 Honeywell MICRO SWITCH Sensing and Control 80 ...
Page 165: ...3 107022 14 EN FR26 GLO 0100 Printed in Germany This page has been left intentionally blank ...
Page 201: ...39 107022 14 EN FR26 GLO 0100 Printed in Germany This page has been left intentionally blank ...
Page 205: ...43 107022 14 EN FR26 GLO 0100 Printed in Germany This page has been left intentionally blank ...
Page 207: ...45 107022 14 EN FR26 GLO 0100 Printed in Germany This page has been left intentionally blank ...
Page 208: ...107022 14 EN FR26 GLO 0100 Printed in Germany 46 9 Declaration of Conformity ...
Page 219: ...11 107006 11 EN FR26 GLO 0300 Printed in Germany This page has been left intentionally blank ...
Page 229: ...21 107006 11 EN FR26 GLO 0300 Printed in Germany This page has been left intentionally blank ...
Page 257: ...49 107006 11 EN FR26 GLO 0300 Printed in Germany This page has been left intentionally blank ...
Page 260: ...107006 11 EN FR26 GLO 0300 Printed in Germany 52 9 3 Declaration of conformity ...
Page 340: ...Safety Perimeter Guarding Installation Manual FF SPS4 Series Safety Perimeter Guarding ...
Page 536: ...2 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Page 538: ...4 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Page 542: ...107004 15 EN FR26 ROW 0899 Printed in France 8 This page has been left intentionally blank ...
Page 620: ...86 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Page 624: ...90 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Page 626: ...92 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Page 627: ...107004 15 EN FR26 ROW 0899 Printed in France 93 8 CE Declaration of Conformity ...
Page 628: ...94 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...