3.5 Mutual Interference or Cross-talk
The FF-SYA Series light curtain is based upon an infrared transmission between an
emitter unit and a receiver unit. It is a safety requirement of the IEC/pr EN 61496-2
standard that if a receiver R2 receives two signals transmitted by two different emitters E1
and E2, the receiver R2 must turn to the alarm state. This happens if the receiver R2 is
within the 2.5° beam aperture angle and within the nominal scanning range of the second
emitter E1, and the cross-talk detection indicator flickers to warn the installer.
MUTUAL INTERFERENCE OR CROSSTALK
Reception of two infrared emissions will maintain the light curtain in a lock-out condition.
To go back to normal operation, switch the power off and eliminate the interferences by
reversing systems emitting orientation or by using opaque screen, or by adjusting the
adequate emission power regarding the application. Then restaure the power.
Figure 3-3 Mutual Interferences between two light curtain sets
R3
R2
R1
alarm
test
E
1
E
1
R
1
R
2
E
2
ON
OFF
R
2
A selector switch is available on the emitter unit for the selection of the adequat emission
power. It can be used to prevent this cross-talk phenomenon by decreasing the nominal
scanning range.
Figure 3-4 Emission Power selector switch
Nominal Scanning Range
(1)
54 % of the Nominal
Scanning Range
(1)
42 % of the Nominal
Scanning Range
(1)
(1): the Nominal Scanning Range is 6 m for the FF-SYA14 light curtain and 18 m for the FF-
SYA30 and FF-SYA60 light curtains (factory settings). To guarantee this nominal scanning range and
the decreased scanning ranges, the devices have a greater effective scanning range with up to 20 %
variations from the nominal values.
F
SYA1
9
F
SYA2
0
F
SYA2
1
F
SYA2
2
F
SYA2
3
F
SYA2
4
Summary of Contents for SYA14 Series
Page 2: ...2 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 6: ...6 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 26: ...26 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 62: ...62 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 70: ...70 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 76: ...76 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 78: ...78 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 79: ...107031 23 EN FR26 GLO 1199 Printed in France 79 8 CE Declaration of Conformity ...
Page 80: ...80 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 84: ......
Page 158: ......
Page 160: ......
Page 161: ...For application help call 1 800 537 6945 Honeywell MICRO SWITCH Sensing and Control 80 ...
Page 165: ...3 107022 14 EN FR26 GLO 0100 Printed in Germany This page has been left intentionally blank ...
Page 201: ...39 107022 14 EN FR26 GLO 0100 Printed in Germany This page has been left intentionally blank ...
Page 205: ...43 107022 14 EN FR26 GLO 0100 Printed in Germany This page has been left intentionally blank ...
Page 207: ...45 107022 14 EN FR26 GLO 0100 Printed in Germany This page has been left intentionally blank ...
Page 208: ...107022 14 EN FR26 GLO 0100 Printed in Germany 46 9 Declaration of Conformity ...
Page 219: ...11 107006 11 EN FR26 GLO 0300 Printed in Germany This page has been left intentionally blank ...
Page 229: ...21 107006 11 EN FR26 GLO 0300 Printed in Germany This page has been left intentionally blank ...
Page 257: ...49 107006 11 EN FR26 GLO 0300 Printed in Germany This page has been left intentionally blank ...
Page 260: ...107006 11 EN FR26 GLO 0300 Printed in Germany 52 9 3 Declaration of conformity ...
Page 340: ...Safety Perimeter Guarding Installation Manual FF SPS4 Series Safety Perimeter Guarding ...
Page 536: ...2 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Page 538: ...4 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Page 542: ...107004 15 EN FR26 ROW 0899 Printed in France 8 This page has been left intentionally blank ...
Page 620: ...86 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Page 624: ...90 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Page 626: ...92 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Page 627: ...107004 15 EN FR26 ROW 0899 Printed in France 93 8 CE Declaration of Conformity ...
Page 628: ...94 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...