number of output pulses is smaller or larger than the calculated number of output pulses
(taget number of feedbacks x percentage value/100), this can be improved by adjusting
the percentage value, acceleration/decelartion time or the target frequency.
Program Example:
1. Assume we choose X0 as the external interrupt, with I001 (rising-edge trigger) interrupt; target
number of feedbacks = 50,000; target frequency = 10KHz; Y0, Y1 (CH0) for the output pulses;
start/end frequency (D1340) = 200Hz; acceleration time (D1343) = 300ms; deceleration time
(D1348) = 600ms; percentage value (D1198) = 100; current number of output pulses (D1336,
D1337) = 0.
MOV
MOV
MOV
K100
K600
K300
D0
M1002
D1198
D1343
D1348
SET
DMOV
K0
D1336
RST
C251
EI
DCNT
C251
K100000
FEND
IRET
END
DCLLM
X0
K50000 K100000
Y0
INC
M1534
M0
M1000
I010
2. Assume the first execution result as:
100KHz
D1340
D1348
D1343
X0 Off --> On
Frequency
Y0 stops output
Time
Number
Estimated number of output pulses: 50,000
Actual number of output pulses (D1336, D1337) = K49,200
Summary of Contents for ELC-PB
Page 1: ......
Page 5: ...For more information visit www eaton com MN05003003E iv...
Page 29: ...ELC Programming Manual For more information visit www eaton com MN05003003E 1 24 MEMO...
Page 502: ...3 Instruction Set MN05003003E For more information visit www eaton com 3 333...
Page 601: ...ELC Programming Manual For more information visit www eaton com MN05003003E 3 432...
Page 625: ...ELC Programming Manual For more information visit www eaton com MN05003003E 3 456...