EL C Pro g rammi ng Manu al
F O R MORE INFORM AT ION VISIT: WWW.E ATON.COM MN05003003E
2-86
Function Group
Input points time delay
Number
D1020~D1021
Contents:
1. ELC-PB/PC/PA/PH, ELCM-PH/PA controllers X0~X7: 10ms (factory default), 0~20ms
adjustable. Refer to the usage of special registers D1020.
2.
ELC-PH controllers X10, X11: 0 times (factory default), 0~20 times adjustable (Scan cycle is
the base). Refer to the usage of special registers D1021.
3.
D1020 can be used for setting up the response time of receiving pulses at X0 ~X7 for ELC-
PV controllers. (Setup range: 0 ~ 60; Unit: ms)
4.
D1021 can be used for setting up the response time of receiving pulses at X10 ~X17 for ELC-
PV controllers. (Setup range: 0 ~ 60; Unit: ms)
5.
When power to the ELC goes from OFF
→
ON, the content of D1020 and D1021 will become
to 10 (default) automatically.
X0
X7
0ms
1ms
10ms
15ms
0
1
10
15
Terminal
response time
state
memory
input reflash
setting by D1020
(default is 10)
6. When setting the X0~X7 response time to 0ms to execute following program, the faster
response time input terminal will be 50
μ
s due to input terminal connection to an RC filter
circuit in series.
M1000
MOV
K0
D1020
normally ON contact
7.
It is not necessary to adjust response time when using high-speed counter or an interrupt in
the program.
8.
It is the same to use instruction REFF or change the content of D1020 and D1021.
Function Group
ELC-PB/PA/PC/PH, ELCB-PB X0 input point can detect pulse width
Number
M1084
、
D1023
Contents:
X0 input point of ELC-PB/PA/PC/PH V1.4, ELCB-PB controllers can detect pulse width. Whenever
X0 turns from ON to OFF, the value will be updated once and stored in D1023 (unit: 0.1ms). The
minimum detectable width is 0.1ms and maximum 10,000ms.
Summary of Contents for ELC-PB
Page 1: ......
Page 5: ...For more information visit www eaton com MN05003003E iv...
Page 29: ...ELC Programming Manual For more information visit www eaton com MN05003003E 1 24 MEMO...
Page 502: ...3 Instruction Set MN05003003E For more information visit www eaton com 3 333...
Page 601: ...ELC Programming Manual For more information visit www eaton com MN05003003E 3 432...
Page 625: ...ELC Programming Manual For more information visit www eaton com MN05003003E 3 456...