EL C Pro g rammi ng Manu al
F O R MORE INFORM AT ION VISIT: WWW.E ATON.COM MN05003003E
2-136
Operation flow chart:
Set starting reference for reading from slave ELC
Set data length to be read on Slave ELC
(ELC will take default or previous setting as the set value
if these registers are not specified)
Set starting reference for writing in Slave ELC
Set data length to be written on Slave ELC
SET M1354
RST M1354
EASY PLC LINK
SET M1351
SET M1352
Communication by
Modbus 0X17 function
Enable
Disable
Manual / Auto mode
Enable auto mode
Enable manual mode
Set times of polling
cycle (D1431)
SET M1350
Start to execute ELC LINK
Disable
Enable
M1355 = ON, auto-detection disabled.
Set the Slave to be linked by M1360~
M1375 manually
M1355
M1350=OFF, Slave ID
auto-detection enabled
Summary of Contents for ELC-PB
Page 1: ......
Page 5: ...For more information visit www eaton com MN05003003E iv...
Page 29: ...ELC Programming Manual For more information visit www eaton com MN05003003E 1 24 MEMO...
Page 502: ...3 Instruction Set MN05003003E For more information visit www eaton com 3 333...
Page 601: ...ELC Programming Manual For more information visit www eaton com MN05003003E 3 432...
Page 625: ...ELC Programming Manual For more information visit www eaton com MN05003003E 3 456...