Installation
Installing Interface Cards
33
CAUTIONT!
Static charges can damage electronic components. Pay atten-
tion to the regulations regarding the handling of electrostati-
cally sensitive components.
3.
Carefully insert the interface card in the slot provided. The component side
must face to the right.
Ensure the plug-in connection is sitting securely.
4.
Connect the required port cable to the corresponding pressure terminals of
the relevant pressure terminal group (see also
Positions of the Ports
starting on
page 37).
5.
Close the housing cover and turn on the OpenCom 100 again.
The software of the OpenCom 100 can detect the type of interface card present.
The interface card must still be configured individually for commissioning.
You can query the status of the interface cards in the Web console when the
OpenCom 100 is operational again. To do this, call up the
PBX Configuration:
Ports: Slots
menu page. The
Status
column of the table displays a green tick
beside the slot name (for an OpenCom 130 e.g.
0/1
,
0/2
and
0/3
). The column of
the table must list the correct type of interface card.