A H 5 0 0 M o t i o n C o n t r o l M o d u l e M a n u a l
5 - 1 5 0
Output pin
Name
Function
Data
type
Time when there is
a transition in an
output pin’s signal
from low to high
Time when there is a
transition in an output pin’s
signal from high to low
Busy
The motion
control
function block
is being
executed.
BOOL
There is a
transition in the
Busy output pin’s
signal from low to
high when there
is a transition in
the Execute input
pin’s signal from
low to high.
There is a transition in
the Busy output pin’s
signal from high to low
when there is a
transition in the Done
output pin’s signal from
low to high.
There is a transition in
the Busy output pin’s
signal from high to low
when there is a
transition in the Error
output pin’s signal from
low to high.
There is a transition in
the Busy output pin’s
signal from high to low
when there is a
transition in the Aborted
output pin’s signal from
low to high.
Aborted
The execution
of the motion
control
function block
is interrupted
by a
command.
BOOL
The execution of
the motion
control function
block is
interrupted by a
command.
There is a transition in
the Aborted output pin’s
signal from high to low
when there is a
transition in the Execute
input pin’s signal from
high to low.
If the Execute input pin
is set to False when the
execution of the motion
control function block is
interrupted, the Aborted
output pin will be set to
False in the next cycle.
Error
An error
occurs in the
motion control
function block.
BOOL
Input values are
incorrect.
The axis
specified is in
motion before the
motion control
function block is
executed.
There is transition in the
Error output pin’s signal
from high to low when
there is a transition in
the Execute input pin’s
signal from high to low.
The number of pulses is a unit for the Distance1 input pin/the Distance2 input pin, and the
number of pulses per second is a unit for the Velocity1 input pin/the Velocity2 input pin. Users
can change the unit used by means of the motion control function block T_AxisSetting2.
3. Troubleshooting
Error
Troubleshooting
The values of input pins in the motion
control function block are incorrect.
Check whether the values of the input pins
are in the ranges allowed.
Summary of Contents for AH500
Page 9: ...viii...
Page 53: ...AH500 Motion Control Module Manual Wiring AH10PM 5A and a Yaskawa servo drive 2 32...
Page 55: ...AH500 Motion Control Module Manual Wiring AH10PM 5A and a Fuji servo drive 2 34...
Page 115: ...AH500 Motion Control Module Manual 4 16 MEMO...
Page 375: ...AH500 Motion Control Module Manual 5 260 MEMO...
Page 383: ...AH500 Motion Control Module Manual 6 8 MEMO...
Page 419: ...AH500 Motion Control Module Manual 7 36 MEMO...
Page 436: ...Chapter 8 Electronic Cam 8 17...
Page 483: ...AH500 Motion Control Module Manual 10 8 MEMO...
Page 505: ...AH500 Motion Control Module Manual 12 8 MEMO...
Page 515: ...AH500 Motion Control Module Manual 13 10 MEMO...
Page 544: ...Appendix A Error Code Table Table of Contents A 1 Error Code Table A 2 A 1...