DMS-R-IM
Installation
April 7, 2021
Digital Modular System - Rinse
3-6
Item
Requirement
Exhaust
Model: DMS-1218
Collar Size:
Ø4”
Quantity
: 2 Ports
Model: DMS-1826
Collar Size:
Ø5”
Quantity
: 2 Ports
Operating
conditions
Humidity: Relative humidity for operation should be
below 70% RH.
Temperature: Approximately 23
C - 26
C
Altitude: Able to operate between sea level to 1,000 m.
Work Place
Environment
To be installed in a
pollution degree 2 environments
.
For
indoor
use only.
Model: DMS-R-1218 & DMS-R-1826
Requirement
DMS-R-1218
DMS-R-1826
Power capacity
240V/3-phase/60Hz/16Amp
(Include Recirculation)
240V/3-phase/60Hz/31Amp
(Include Recirculation)
Number of Wire
4
4
Max. Cir. Protection
Rating
20Amp
(Include Recirculation)
40Amp
(Include Oil Coalescer and
Recirculation)
Maximum Load
Rating
7.2Amp
(Include Recirculation)
14.5Amp
(Include Recirculation)
Ampere Interrupting
Capacity
10kA
10kA
Short-Circuit Current
Rating
5kA
5kA
Electrical Drawing
DMS-1218-R-E01
DMS-1826-R-E01