DMS-R-IM
Interpreting HMI
April 7, 2021
Digital Modular System - Rinse
5-13
Figure 5-9: Rinse Station Manual Function screen (DMS-1218 & DMS-1826)
Button
Description
(Aqua = OFF/Unlatched; Green = ON/Latched)
[HEATER]
Press to turn ON/OFF Rinse Station heater module.
*
[PUMP]
Press to turn ON/OFF Rinse Station recirculation pump.
[FILL]
Press to turn ON/OFF Rinse Station fill solenoid valve.
Note
: Only applicable when Auto Fill feature is
purchased.
Manual
mode operation: Fill solenoid valve turns ON
when this button is triggered. It automatically turns
OFF when fill time is complete. Fill time is configured
in Misc. 5 screen. Alternatively, press again this button
to turn OFF fill solenoid valve.
Auto
mode operation: Fill solenoid valve turns ON
and OFF according to the option selected in Auto
Options screen, either Basket In Tank Fill or Basket
Timed Fill.
[DRAIN]
Press to turn ON/OFF Rinse Station drain solenoid valve.
*
[WEIR PUMP] Press to turn ON/OFF Rinse Station weir pump.
*
[DRAIN WEIR]
Press to turn ON/OFF Rinse Station overflow weir drain
valve. During
Manual
mode operation: Drain weir
solenoid valve turns ON when this button is triggered. It
automatically turns OFF when drain weir time is
complete. Drain weir time is configured in Misc. 4 screen.
Alternatively, press again this button to turn OFF drain
weir solenoid valve.
(Pink = OFF/Unlatched; Green = ON/Latched)