DMS-R-IM
Safety
April 7, 2021
Digital Modular System - Rinse
1-15
1.11.1
Live After EMO
NOTE
Please refer to relevant electrical drawing or schematic for
more detail.
The EMO circuit, when activated, shuts off all energy to the system
EXCEPT
:
Noise Filter
Power Supply Input 240VAC Output 24VDC 5A
PLC
Refer to electrical schematics for more information.
Do not touch any other components listed above as these components are still
energized.
1.11.2
Recover from Emergency OFF
Follow instruction below to recover from emergency
OFF
:
Step
Description
1
Rectify and solve the problem.
2
Release
[EMO]
button by turning
[EMO]
(red button) button
clockwise until the button pops out.
3
Press on [SYSTEM ON] button and follow operating instruction in
section 4.