DMS-R-IM
System Overview
April 7, 2021
Digital Modular System - Rinse
2-11
Item
Feature
Frequency
Upgrade
Option 1B:
Choose from single frequency 40kHz.
Includes DS series module upgrades located within
cabinet at standard case assembly.
Includes Direct Bonded frequency transducer
assemblies.
Option 1C:
Choose from single frequency: 40/58kHz, 40/132kHz
and 40/192kHz.
Includes DS/MW series module upgrades located
within cabinet at standard case assembly.
Includes Direct Dual-Bonded frequency transducer
assemblies. Frequencies are split 1000W wach in a
specially designed array.
Option 1D:
Choose from single frequency: 58kHz, 132kHz and
192kHz or from dual frequency combinations
58/132kHz, 58/192kHz and 132/192kHz.
Includes MW series module upgrades located within
cabinet at standard case assembly.
Includes Direct Bonded single and Direct Dual-
Bonded frequency transducer assemblies.
Frequencies are 2000W single or split 1000W each in
a specially designed array.
Option 1E:
Choose from MEGAsonic frequencies: 280kHz,
360kHz, 470kHz, 720kHz and 1000kHz.
Includes MEGAsonic series module upgrades
located within cabinet at standard case assembly.
Transducer array is mounted on a specially designed
plate which is inverted down and bolted through
bottom of tank with Teflon gasketing. Wattage range
is 2000W.
Timed Cascade
Over-Flow
Package
(Option 1F)
An electrically-actuated solenoid valve on the
incoming line.
Include a manual bypass line control by manual ball
valve.
PLC controlled timer during process or monitor
controlled with options purchased.