DMS-R-IM
Preventive Maintenance
April 7, 2021
Digital Modular System - Rinse
6-10
6.5.7
Perform PM for Bucket Strainer (Tee-Line Strainer)
(Optional Item)
Item
PM Activity/Schedule
Gasket/Elastomer Inspect gasket/elastomer if any damage.
Y
Insert
Check & clean insert.
M
(D–daily; W–weekly; M–monthly;, Q–quarterly; HY–half-yearly; Y–yearly; TBD–to be determine)
Strainer Bucket is used to catch foreign materials out of the pumps, valves and
process equipment. This Tee-Line Bucket Strainer is installed before the suction
end of the pump and use of bucket strainer will prevent blockage inside
plumbing and avoid damage to the pump. Refer to
6.5.7.1 for Insert Orientation
.
Figure 6-4: Bucket strainer and recirculation pump
Figure 6-5: Bucket strainer
Step
Description
1
Power OFF the system.
Recirculation
Pump
Bucket Strainer
Tri-clamp
Body Tee-Line
Strainer
Insert
Gasket