DMS-R-IM
Operation
April 7, 2021
Digital Modular System - Rinse
4-24
Step
Description
Images illustration
5
*continue from previous page
In Misc. 4 screen, configure:
Set resistivity low alarm limit set
point (Mohm).
Set refill trigger offset and refill
cutoff hysteresis.
Set weir pump delay off time
setting (sec).
Set manual timed drain weir
setting (sec) (Apply for
Manual
mode operation), if necessary.
Press [Next] to go to Misc. 5 screen.
In Misc. 5 screen, configure:
Set pH high and low alarm limit
set point (pH).
Set manual timed fill setting (sec)
(Apply for
Manual
mode
operation), if necessary.
Set recirculation flowrate low
alarm limit set point (GPM).
Press [Next] to go to Misc. 6 screen.
In Misc. 6 screen, cycle count of each
station valve, contactor and cylinder
are displayed. Press relevant [Reset]
button upon replacing any
component.
Note
: “
*OPTIONAL
” wording will
be displayed if the option is not
purchased by user or option is not
enabled in the Setup 6 screen.
Please refer to section
5.7 Misc.
Screen
for detail description.
Press on [Main Menu] at bottom
right corner button to return to Main
Menu screen.
Misc. 4 screen(DMS-1218 & DMS-1826)
Misc. 5 screen(DMS-1218 & DMS-1826)
Misc. 6 screen(DMS-1218 & DMS-1826)