DMS-R-IM
Operation
April 7, 2021
Digital Modular System - Rinse
4-19
4.7.1
View and Change Tank Temperature Settings
Follow instruction below to view and change tank temperature settings:
Step
Description
Images illustration
1
Log into
Engineer
or
Maintenance
level. Refer
section
for
procedure.
2
At Main Menu screen, press on
[Temperature Control] button.
3
Temperature Control screen as
shown will prompt.
These screen will displays:
Present Value
– real time
display current temperature.
Temp. Set Point (F)
–
optimum operating
temperature. Temperature
setting range is 70°F to 175°F
(20°C to 80°C).
Temp. Low
Alarm (F)
–
lowest operating
temperature. Temperature
setting range 45°F to 200°F
(5°C to 95°C).
Temp. High
Alarm (F)
–
highest operating
temperature. Temperature
setting range is 45°F to 200°F
(5°C to 95°C).