Replacing the Desiccant Wheel
Assembly
(W600 - 1000)
(continued)
10
Lift the new desiccant wheel into the dryer frame, being sure it is ori-
ented properly.
To verify the correct orientation, ensure that the regener-
ation air inlet is positioned closest to the regeneration heater tube.
DO
NOT
bolt into place at this time.
11
If the dryer aftercooler is being used,
slide the desiccant wheel assembly
towards the front of the dryer, being careful to not let it slip off one
side of the dryer frame.
Position the aftercooler assembly into the dryer
frame and bolt it to the rear panel.
12
Position the desiccant wheel assembly and bolt it in place.
13
Bolt the aftercooler to the desiccant wheel assembly.
14
If the aftercooler is being used, reconnect the water lines.
15
Reconnect or reinstall all hoses, RTDs, and wiring connections.
16
Bolt the top cover in place.
17
Connect the power to the dryer and start it.
Ensure that the desiccant
wheel assembly rotates in the correct direction.
18
Replace all upper and lower side panels.
6-38
l Tr o u b l e s h o o t i n g
Summary of Contents for HTC 120
Page 10: ...viii l Table of Contents ...
Page 30: ...2 14 l Description ...
Page 35: ...Installation General Installation General l 3 5 3 I n s t a l l a t i o n ...
Page 65: ...Installation Hard Piping Kits Installation Piping Hoses l 3 35 3 I n s t a l l a t i o n ...
Page 80: ...3 50 l Installation Piping Hoses ...
Page 88: ...3 58 l Installation Piping Hoses ...
Page 92: ...3 62 l Installation Conveying Lines ...
Page 93: ...Installation Water Lines 3 I n s t a l l a t i o n Installation Water Lines l 3 63 ...
Page 124: ...3 94 l Installation Gas Piping and Exhaust Flue ...
Page 125: ...Installation Testing 3 I n s t a l l a t i o n Installation Testing l 3 95 ...
Page 250: ...4 108 l Operation ...
Page 286: ...5 36 l Maintenance ...