Cleaning the Aftercooler/
Intercooler Coils
You need to clean the aftercooler/intercooler coils to keep them working efficient-
ly. Cleaning frequency depends on the type and amount of material you process.
1
Stop the dryer and lockout the main power.
2
Turn off the water flow to the water supply line.
Disconnect
supply and return lines.
3
Remove the bolts securing the aftercooler/intercooler cover.
Remove the
cover.
4
Remove the aftercooler/intercooler by pulling it out
of the aftercooler/inter-
cooler housing.
W600 - 1000
Models
W1600 - 5000
Models
NOTE:
If an optional flow control was added with the aftercooler/intercooler, remove the
compression fitting from the aftercooler/intercooler inlet. Loosen the fitting on the flow
control, then swing the copper water supply tube out and away from the
aftercooler/intercooler inlet.
✐
(continued)
ON
O
O
FF
M a i n t e n a n c e l
5-19
5
M
ai
n
te
n
an
ce
Summary of Contents for HTC 120
Page 10: ...viii l Table of Contents ...
Page 30: ...2 14 l Description ...
Page 35: ...Installation General Installation General l 3 5 3 I n s t a l l a t i o n ...
Page 65: ...Installation Hard Piping Kits Installation Piping Hoses l 3 35 3 I n s t a l l a t i o n ...
Page 80: ...3 50 l Installation Piping Hoses ...
Page 88: ...3 58 l Installation Piping Hoses ...
Page 92: ...3 62 l Installation Conveying Lines ...
Page 93: ...Installation Water Lines 3 I n s t a l l a t i o n Installation Water Lines l 3 63 ...
Page 124: ...3 94 l Installation Gas Piping and Exhaust Flue ...
Page 125: ...Installation Testing 3 I n s t a l l a t i o n Installation Testing l 3 95 ...
Page 250: ...4 108 l Operation ...
Page 286: ...5 36 l Maintenance ...