4
O
p
er
at
io
n
O p e r a t i o n l
4-103
Using the OptiMizer™
(continued)
The bottom display section of this screen shows the setpoints of the currently
selected recipe (after the ‘View Recipe’ button has been pushed) and the setpoints
currently stored in the controller. The following is a description of the buttons
associated with the bottom recipe setpoints display.
The following table shows all of the setpoints and settings in a typical recipe.
Each setting and setpoint will have a description, minimum, and maximum range.
Shows the status of the current recipe function. The
download, upload, create, restore, save, and delete func-
tions show a status in this box that shows progress,
completion, and errors. After a function button has
been selected, a delay occurs before the system will
update the status.
Name
Min
Max
Description
Pre-dry Airflow
(%)
20
100
Airflow, when in Pre-dry, used if the Variable
Speed Drive providing the airflow is in Fixed
Frequency (manual) mode.
Pre-dry Airflow
Flow (CFM)
200
5000
Airflow, when in Pre-dry, used if the Variable
Speed Drive providing the airflow is in PID
Control (automatic) mode. This is the recom-
mended mode of control for the airflow when
using OptiMizer™.
Pre-dry
Temperature (°F)
80
375
Air delivery temperature setpoint when in Pre-
dry.
Dynamic Airflow
(%)
20
100
Airflow setpoint for the Optimized recipe in
Ramp Down mode, used if the Variable Speed
Drive providing the airflow is in Fixed
Frequency (manual) mode.
Dynamic Airflow
Flow (CFM))
200
5000
Airflow setpoint for the Optimized recipe in
Ramp Down mode, used if the Variable Speed
Drive providing the airflow is in PID Control
(automatic) mode. This is the recommended
mode of control for the airflow when using
OptiMizer™.
Dynamic
Temperature (°F)
80
375
Air delivery temperature setpoint for the
Optimized recipe in Ramp Down mode.
(continued)
Summary of Contents for HTC 120
Page 10: ...viii l Table of Contents ...
Page 30: ...2 14 l Description ...
Page 35: ...Installation General Installation General l 3 5 3 I n s t a l l a t i o n ...
Page 65: ...Installation Hard Piping Kits Installation Piping Hoses l 3 35 3 I n s t a l l a t i o n ...
Page 80: ...3 50 l Installation Piping Hoses ...
Page 88: ...3 58 l Installation Piping Hoses ...
Page 92: ...3 62 l Installation Conveying Lines ...
Page 93: ...Installation Water Lines 3 I n s t a l l a t i o n Installation Water Lines l 3 63 ...
Page 124: ...3 94 l Installation Gas Piping and Exhaust Flue ...
Page 125: ...Installation Testing 3 I n s t a l l a t i o n Installation Testing l 3 95 ...
Page 250: ...4 108 l Operation ...
Page 286: ...5 36 l Maintenance ...