5-20
l M a i n t e n a n c e
Cleaning the Aftercooler/
Intercooler Coils
(continued)
5
Clean the assembly using a mild soap and water.
Let the assembly
dry thoroughly before installation.
NOTE:
In cases of heavy volatiles, steam cleaning or the use of solvents, such
as acetone, may be necessary. Be sure to test a small area with the solvent
you have selected to be sure there is no adverse reaction.
6
Inspect the condition of the gasket.
If it is damaged, replace the
gasket.
7
Reassemble
by repeating the steps in reverse order.
8
Connect the water supply line to the inlet.
If a manual shut off
valve is used, it should be mounted on the inlet line as well.
9
Connect the outlet of the aftercooler/intercooler to the inlet of the
flow control valve
using the pre-shaped copper tubing and compres-
sion fittings provided.
✐
Replacement gaskets are
available from Conair.
Contact Conair Parts
(800) 458 1960
From outside of the
United States, call:
(814) 437 6861
Summary of Contents for HTC 120
Page 10: ...viii l Table of Contents ...
Page 30: ...2 14 l Description ...
Page 35: ...Installation General Installation General l 3 5 3 I n s t a l l a t i o n ...
Page 65: ...Installation Hard Piping Kits Installation Piping Hoses l 3 35 3 I n s t a l l a t i o n ...
Page 80: ...3 50 l Installation Piping Hoses ...
Page 88: ...3 58 l Installation Piping Hoses ...
Page 92: ...3 62 l Installation Conveying Lines ...
Page 93: ...Installation Water Lines 3 I n s t a l l a t i o n Installation Water Lines l 3 63 ...
Page 124: ...3 94 l Installation Gas Piping and Exhaust Flue ...
Page 125: ...Installation Testing 3 I n s t a l l a t i o n Installation Testing l 3 95 ...
Page 250: ...4 108 l Operation ...
Page 286: ...5 36 l Maintenance ...