Testing the Installation of the
GasTrac
(continued)
7
Verify the combustion blower is rotating in the correct direction.
The
combustion blower uses a three-phase blower. Hold a strip of paper or piece
of string near the blower inlet filter. If the paper or string blows away from
the filter, the blower is rotating in the
wrong
direction. Stop the GasTrac.
Disconnect and lockout the main power source. Reverse any two incoming
electrical leads on the blower at the VFD output and repeat the test procedure.
8
Allow the actual temperature to reach setpoint.
9
Once the setpoint is reached, press the “STOP” button.
• The green RUN indicator light turns off.
• The gas inlet valves should close.
• The combustion blower should stop.
• The burner and temperature controllers should display STANDBY.
10
After the test has been completed successfully,
turn off the power to the
GasTrac, allow to cool, and properly shut down the dryer,
see Operation
section entitled, Stopping the EnergySmart Dryer System.
Combustion
Blower Inlet
Filter
3-104
l I n s t a l l a t i o n - Te s t i n g
IMPORTANT:
Always refer
to the wiring diagrams that
came with your GasTrac
before making electrical
connections.
IMPORTANT:
Always refer
to the wiring diagrams that
came with your GasTrac
before making electrical
connections.
Summary of Contents for HTC 120
Page 10: ...viii l Table of Contents ...
Page 30: ...2 14 l Description ...
Page 35: ...Installation General Installation General l 3 5 3 I n s t a l l a t i o n ...
Page 65: ...Installation Hard Piping Kits Installation Piping Hoses l 3 35 3 I n s t a l l a t i o n ...
Page 80: ...3 50 l Installation Piping Hoses ...
Page 88: ...3 58 l Installation Piping Hoses ...
Page 92: ...3 62 l Installation Conveying Lines ...
Page 93: ...Installation Water Lines 3 I n s t a l l a t i o n Installation Water Lines l 3 63 ...
Page 124: ...3 94 l Installation Gas Piping and Exhaust Flue ...
Page 125: ...Installation Testing 3 I n s t a l l a t i o n Installation Testing l 3 95 ...
Page 250: ...4 108 l Operation ...
Page 286: ...5 36 l Maintenance ...