Installation guide
ACOPOSinverter P84 User's Manual 2.10
39
1.3.4.1.4 8I84T201500.01P-1, 8I84T201850.01P-1, 8I84T202200.01P-1
Model number
8I84T201500.01P-1
8I84T201850.01P-1
8I84T202200.01P-1
General information
Certifications
CE
Yes
KC
Yes
UL
cULus E225616
Power conversion equipment
Motor power
Listed on nameplate
15 kW
20 PS
18.5 kW
25 PS
22 kW
30 PS
Mains connection
Mains input voltage
3x 200 VAC -15% to 240 VAC +10%
Frequency
50 to 60 Hz ±5%
Apparent power (at 240 VAC)
25.6 kVA
28.7 kVA
33.3 kVA
Max. assumed short circuit current (lsc)
(short circuit current at connection point)
22 kA
Max. mains current with optional mains choke
At 230 VAC
50.0 A
60.9 A
71.0 A
Mains current
At 200 VAC
71.7 A
77 A
88 A
At 240 VAC
61.6 A
69 A
80 A
Power dissipation at nominal load and nominal
clock frequency
620 W
657 W
766 W
Integrated EMC filter
No
1)
Line-conducted and radiated emissions
With add-on filter
8I0FT072.300-1
8I0FT090.300-1
With add-on filter
Motor cable length per IEC/EN 61800-3
Cat. C1 environment 1 (public power system)
≤50 m / ≤25 m
2)
≤50 m / ≤25 m
3)
Motor cable length per IEC/EN 61800-3
Cat. C2 environment 1 (public power system)
≤100 m / ≤50 m
4)
≤100 m / ≤50 m
5)
Motor cable length per IEC/EN 61800-3
Cat. C3 environment 2 (industrial power system)
≤100 m / ≤50 m
4)
≤100 m / ≤50 m
5)
Motor connection
Derating of continuous output current depending on
ambient temperature
At nominal clock frequency (4 kHz or 2.5 kHz
with higher inverter power)
No derating (up to 50°C)
Other clock frequencies
The derating curves are included in the installation instructions, which
can be downloaded from the website (www.br-automation.com).
Derating of continuous output current depending on
installation elevation
Starting at 1000 m above sea level
1%, per 100 m
Max. continuous output current (In)
At 230 VAC
66 A
6)
75 A
6)
88 A
6)
Max. transient current for 60 s
99 A
112 A
132 A
Max. transient current for 2 s
109 A
124 A
145 A
Output frequency range
0.5 to 599 Hz
Nominal clock frequency
4 kHz
2.5 kHz
Nominal clock frequency
Min.
1 kHz
Max.
16 kHz
Short-term overload torque (typical value)
170% of the motor's rated torque (typical value at ±10%) for 60 s
220% of the motor's rated torque (typical value at ±10%) for 2 s
Braking torque
With braking resistor
Up to 150% of the rated motor torque
Without braking resistor (typical value)
30% of the rated motor torque
Max. motor cable length
Shielded cable
100 m
6)
Non-shielded cable
150 m
6)
Closed-loop motor control profiles
Induction motor
Flux vector control (FVC) with encoder (voltage vector) (current vector)
Flux vector control (SFVC) without encoder (voltage or current vector)
Voltage/frequency ratio - V/f characteristic curve (2 or 5 points)
ENA energy adjustment system for asymmetrical loads
Main protective functions of inverter
Thermal protection against power stage overheating
Protection against short circuits between the motor phases, line phase failures, over-
current between output phases and ground, overvoltages on the DC bus, interrup-
tions in the control loop, exceeding the speed limit. Safety function for: Over- and
undervoltage of the power supply system, line phase failure with 3-phase supply
Table 13: 8I84T201500.01P-1, 8I84T201850.01P-1, 8I84T202200.01P-1 - Technical data
Summary of Contents for ACOPOSinverter P84
Page 2: ......
Page 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Page 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Page 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Page 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Page 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Page 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...