Installation guide
ACOPOSinverter P84 User's Manual 2.10
49
1.3.4.1.7 8I84T400400.01P-1, 8I84T400550.01P-1, 8I84T400750.01P-1, 8I84T401100.01P-1
Model number
8I84T400400.01P-1
8I84T400550.01P-1
8I84T400750.01P-1
8I84T401100.01P-1
General information
Certifications
CE
Yes
KC
Yes
UL
cULus E225616
Power conversion equipment
Motor power
Listed on nameplate
4 kW
5 PS
5.5 kW
7.5 PS
7.5 kW
10 PS
11 kW
15 PS
Mains connection
Mains input voltage
3x 380 VAC -15% to 480 VAC +10%
Frequency
50 to 60 Hz ±5%
Apparent power (at 380 VAC)
9.3 kVA
13.4 kVA
17.8 kVA
24.1 kVA
Max. assumed short circuit current
(lsc)
(short circuit current at connection
point)
5 kA
22 kA
Max. mains current with optional
mains choke
At 400 VAC
8.3 A
11.4 A
15 A
21.9 A
Mains current
At 380 VAC
14.1 A
20.3 A
27 A
36.6 A
At 480 VAC
11.5 A
17 A
22.2 A
30 A
Power dissipation at nominal load and
nominal clock frequency
144 W
185 W
217 W
320 W
Integrated EMC filter
Yes
1)
Line-conducted and radiated emissions
With integrated filter
Motor cable length per IEC/EN
61800-3
Cat. C1 environment 1 (public pow-
er system)
-
Motor cable length per IEC/EN
61800-3
Cat. C2 environment 1 (public pow-
er system)
≤10 m / ≤5 m
2)
-
Motor cable length per IEC/EN
61800-3
Cat. C3 environment 2 (industrial
power system)
≤10 m / ≤5 m
2)
With add-on filter
8I0FT026.300-1
8I0FT035.300-1
8I0FT046.300-1
With add-on filter
Motor cable length per IEC/EN
61800-3
Cat. C1 environment 1 (public pow-
er system)
≤50 m / ≤20 m
3)
Motor cable length per IEC/EN
61800-3
Cat. C2 environment 1 (public pow-
er system)
≤100 m / ≤50 m
4)
Motor cable length per IEC/EN
61800-3
Cat. C3 environment 2 (industrial
power system)
≤100 m / ≤50 m
4)
Motor connection
Derating of continuous output current
depending on ambient temperature
At nominal clock frequency (4 kHz
or 2.5 kHz with higher inverter pow-
er)
No derating (up to 50°C)
Other clock frequencies
The derating curves are included in the installation instructions, which
can be downloaded from the website (www.br-automation.com).
Derating of continuous output current
depending on installation elevation
Starting at 1000 m above sea level
1%, per 100 m
Max. continuous output current (In)
At 380 VAC
10.5 A
5)
14.3 A
5)
17.6 A
5)
27.7 A
5)
At 460 VAC
7.6 A
5)
11 A
5)
14 A
5)
21 A
5)
Max. transient current for 60 s
15.8 A
21.5 A
26.4 A
41.6 A
Max. transient current for 2 s
17.3 A
23.6 A
29 A
45.7 A
Output frequency range
0.5 to 599 Hz
Nominal clock frequency
4 kHz
Nominal clock frequency
Min.
1 kHz
Max.
16 kHz
Table 16: 8I84T400400.01P-1, 8I84T400550.01P-1, 8I84T400750.01P-1, 8I84T401100.01P-1 - Technical data
Summary of Contents for ACOPOSinverter P84
Page 2: ......
Page 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Page 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Page 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Page 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Page 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Page 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...