Accessories
378
ACOPOSinverter P84 User's Manual 2.10
4.5 Additional EMC filters
4.5.1 Order data
Model number
Short description
Figure
ACOPOSinverter P84 - Additional EMC input filters
8I0FT012.300-1
EMC filter 3-phase 12 A, bottom or side installation, for
ACOPOSinverter P84 3x 200 to 240 V, 0.37 to 1.5 kW and 3x
380 to 480 V, 0.75 to 2.2 kW
8I0FT026.300-1
EMC filter 3-phase 26 A, bottom or side installation, for
ACOPOSinverter P84 3x 200 to 240 V, 2.2 to 4 kW and 3x 380
to 480 V, 3 to 4 kW
8I0FT035.300-1
EMC filter 3-phase 35 A, bottom or side installation, for
ACOPOSinverter P84 3x 200 to 240 V, 5.5 kW and 3x 380 to
480 V, 5.5 to 7.5 kW
8I0FT046.300-1
EMC filter 3-phase 46 A, bottom or side installation, for
ACOPOSinverter P84 3x 200 to 240 V, 7.5 kW and 3x 380 to
480 V, 11 kW
8I0FT072.300-1
EMC filter 3-phase 72 A, bottom or side installation, for
ACOPOSinverter P84 3x 200 to 240 V, 11 to 15 kW and 3x 380
to 480 V, 15 to 18.5 kW
8I0FT090.300-1
EMC filter 3-phase 90 A, bottom or side installation, for
ACOPOSinverter P84 3x 200 to 240 V, 18.5 to 22 kW and 3x
380 to 480 V, 22 kW
8I0FT092.300-1
EMC filter 3-phase 92 A, bottom or side installation for
ACOPOSinverter P84/P76 3x 380 to 480 V, 37 kW
8I0FT180.300-1
EMC filter 3-phase 180 A, bottom or side installation, for
ACOPOSinverter P84 3x 200 to 240 V, 30 to 45 kW and 3x 380
to 480 V, 45 to 75 kW
Table 28: 8I0FT012.300-1, 8I0FT026.300-1, 8I0FT035.300-1, 8I0FT046.300-1,
8I0FT072.300-1, 8I0FT090.300-1, 8I0FT092.300-1, 8I0FT180.300-1 - Order data
4.5.2 Technical data
Model number
8I0FT012.300-1
8I0FT026.300-1
8I0FT035.300-1
General information
Certifications
CE
Yes
KC
Yes
Mains connection
Max. nominal voltage
3x 480 VAC +10%
Nominal filter current
12 A
26 A
35 A
Max. fault current
At 200 to 240 VAC
4 mA
4.4 mA
3 mA
At 380 to 480 VAC
7 mA
8 mA
7 mA
Power dissipation
At 200 to 240 VAC
10 W
18 W
24 W
At 380 to 480 VAC
5 W
6 W
14 W
Operating conditions
Installation at elevations above sea level
0 to 1000 m
Degree of protection per EN 60529
IP21 and IP41 on upper part
Max. relative humidity per IEC 60068-2-3
93%, non-condensing
No dripping water
Ambient temperature
-10 to 50°C
Maximum installation elevation
3000 m
1)
Environmental conditions
Temperature
Storage
-40 to 65°C
Mechanical characteristics
Weight
2.2 kg
4.0 kg
5.8 kg
Installation
Below or next to the inverter
General information
Conformity to standard
EN 133200
Table 29: 8I0FT012.300-1, 8I0FT026.300-1, 8I0FT035.300-1 - Technical data
1)
From 1000 to 3000 m, current reduced by 1% per 100 m, limited to 2000 m for a grounded phase distribution network.
Summary of Contents for ACOPOSinverter P84
Page 2: ......
Page 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Page 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Page 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Page 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Page 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Page 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...