Integrated safety functions
ACOPOSinverter P84 User's Manual 2.10
363
Note:
For preventive maintenance, the function "power removal" must be activated at least once a year.
Before the preventive maintenance, the supply voltage of the inverter must be switched off and then
back on.
The signals of the logic outputs of the inverter cannot be considered as safety-relevant signals.
Install suppressors in all inductive control circuits that are in the vicinity of the inverter or connected
to the same circuit (relays, contactors, solenoid valves, etc.).