Programming guidelines
ACOPOSinverter P84 User's Manual 2.10
177
[R1 CONFIGURATION] (r1-)
Code
Name/Description
Setting range
Factory settings
r1-
[R1 CONFIGURATION]
r1
[R1 CONFIGURATION]
[no fault]
(FLt)
nO
[No]
(nO)
: Not active
FLt
[no fault]
(FLt)
: Drive without fault (relay switches on in normal state and falls away in faulty state)
rUn
[Start Motor]
(rUn)
: Drive in operation
FtA
[Thresh. Freq. err.]
(FtA)
: Frequency threshold is reached (
[F.-Thresh. Mot]
(Ftd)
)
FLA
[HSP err.]
(FLA)
: High frequency attained
CtA
[Thresh. I err.]
(CtA)
: Current threshold value reached (
[current threshold]
(Ctd)
)
SrA
[FRH err.]
(SrA)
: Frequency reference reached
tSA
[Th Status Motor err]
(tSA)
: Motor thermal state 1 reached
PEE
[PID error alarm]
(PEE)
: PID controller error alarm
PFA
[Al. PID feedb.]
(PFA)
: PID alarm feedback
AP2
[AI2 Al. 4-20]
(AP2)
: Alarm 4-20 mA signal at AI2 input not available
F2A
[Thresh. Freq. 2 err.]
(F2A)
: Threshold frequency reached
[Thresh. freq. 2]
(F2d)
)
tAd
[Th FU err]
(tAd)
: Thermal state of the inverter is reached
rSdA
[Rope spg al.]
(rSdA)
: Slack rope (see parameter
[Config. slack rope]
(rSd)
)
FLA
[Alarm high torque]
(ttHA)
: Motor torque exceeds upper threshold
[Torque thd. high]
(ttH)
ttLA
[Alarm low torque]
(ttLA)
: Motor torque below lower threshold
[Torque thd. low]
(ttL)
MFrd
[Forward]
(MFrd)
: Motor rotating in the forward direction (right)
MrrS
[Reverse]
(MrrS)
: Motor rotating in the reverse direction (left)
tS2
[Th Status Motor 2 err]
(tS2)
: Motor thermal state 2 reached
tS3
[Th Status Motor 3 err]
(tS3)
: Motor thermal state 3 reached
AtS
[Negative torque]
(AtS)
: Negative torque (brakes)
CnF0
[Config.0]
(CnF0)
: Configuration 0 active
CnF1
[Config.1]
(CnF1)
: Configuration 1 active
CnF2
[Config.2]
(CnF2)
: Configuration 2 active
CFP1
[Set 1 active]
(CFP1)
: Parameter set 1 active
CFP2
[Set 2 active]
(CFP2)
: Parameter set 2 active
CFP3
[Set 3 active]
(CFP3)
: Parameter set 3 active
dbL
[Load DC Bus]
(dbL)
: Load of the DC bus
brS
[Brake active]
(brS)
: Drive braking
PrM
[P locked]
(PrM)
: Drive locked by "power removal" input
MCP
[I Mot pres]
(MCP)
: Motor current present
LSA
[EM active]
(LSA)
: Limit switch reached
dLdA
[Alarm load variation]
(dLdA)
: Detection of a load variation
AG1
[Alarmgr1]
(AG1)
: Alarm group 1
AG2
[Alarmgr2]
(AG2)
: Alarm group 2
AG3
[Alarmgr3]
(AG3)
: Alarm group 3
P1A
[Alarm PTC1]
(P1A)
: Alarm PTC sensor 1
P2A
[Alarm PTC2]
(P2A)
: Alarm PTC sensor 2
PLA
[Al. LI6=PTC]
(PLA)
: Alarm PTC sensor LI6=PTC
EFA
[Al ext fault]
(EFA)
: Alarm external fault
USA
[Undervoltage]
(USA)
: Alarm for an undervoltage
UPA
[Voral. UVF]
(UPA)
: Prevention of undervoltage
AnA
[Al haul err.]
(AnA)
: Alarm for a hauling error
tHA
[Al. °C ATV]
(tHA)
: Drive overheating
bSA
[Al load mvt]
(bSA)
: Alarm speed during braking
bCA
[AI Brcont]
(bCA)
: Alarm brake contact
SSA
[Limt T/I err]
(SSA)
: Alarm torque limiting
rtA
[Al. T. contr.]
(rtA)
: Alarm torque control
tJA
[Alarm IGBT]
(tJA)
: Alarm IGBT
bOA
[Al. brake res.]
(bOA)
: Alarm temperature of the braking resistor
rdY
[ready]
(rdY)
: Drive ready
r1d
[R1 Delay time]
0 to 60000 ms
1)
0
The status change is only effective after the configured time as soon as the information is TRUE. In the assignment
[no fault]
(Flt),
, the delay
is not adjustable and remains at 0.
r1S
[R1 Active at]
[1]
(POS)
Configuration of the function logic:
POS
[1]
(POS)
: State 1 when the information is TRUE.
nEG
[0]
(nEG)
: State 0 when the information is TRUE.
In the assignment
[no fault]
(FLt)
, the configuration
[1]
(POS)
cannot be changed.
r1H
[R1 holding time]
0 to 9999 ms
0
The status change is only effective after the configured time as soon as the information is UNTRUE.
In the assignment
[no fault]
(Flt)
, the hold time is not adjustable and remains at 0.
1)
0 to 9999 ms then 10.00 to 60.00 s on the integrated display terminal.
Summary of Contents for ACOPOSinverter P84
Page 2: ......
Page 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Page 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Page 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Page 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Page 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Page 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...