Programming guidelines
ACOPOSinverter P84 User's Manual 2.10
205
[RAMP] (rPt-)
Code
Name/Description
Setting range
Factory settings
rPt-
[RAMP]
rPt
[Ramp type]
[Linear]
(LIn)
LIn
[Linear]
(LIn)
S
[S ramp]
(S)
U
[U ramp]
(U)
CUS
[customer-spec]
(CUS)
S-ramps
FrS
FrS
The rounding coefficient is constant, where t2 = 0.6 x t1 and t1 = set
ramp time.
U ramps
The rounding coefficient is constant, where t2 = 0.5 x t1 and t1 = set
ramp time.
Customized ramps
tA1: Can be set between 0 and 100%
tA2: Can be set between 0 and (100%- tA1)
tA3: Can be set between 0 and 100%
tA4: Can be set between 0 and (100%- tA3)
As a percentage of t1, where t1 = set ramp time
Inr
[Ramp increment]
1)
[0.1]
(0.1)
0.01
[0.01]
: Accelerate until 99.99 seconds
0.1
[0.1]
: Accelerate until 999.9 seconds
1
[1]
: Accelerate until 6000 seconds
This parameter is used for
[acceleration time]
(ACC)
,
[deceleration time]
(dEC)
,
[acceleration time 2]
(AC2)
and
[deceleration time2]
(dE2)
.
ACC
[Acceleration]
1)
0.01 to 6000 s
2)
3 s
Time for the ramp-up from 0 to
[Rated motor frequency]
(FrS)
. Make sure that this value is compatible with the frequency inverter's moment
of inertia.
dEC
[Deceleration]
1)
0.01 to 6000 s
2)
3 s
Time for the deceleration of the
[rated motor frequency]
(FrS)
until 0. Make sure that this value is compatible with the frequency inverter's
moment of inertia.
tA1
[Begin Acc round]
1)
0 to 100%
10%
•
Rounding of the start of the acceleration in % of the acceleration time
[acceleration time]
(ACC)
or
[acceleration time 2]
(AC2)
.
•
Can be set between 0 and 100%
•
The parameter is accessible if
[Ramp Type]
(rPt)
is
[customer spec]
(CUS)
type.
tA2
[End Acc round]
1)
10%
•
Rounding of the end of the acceleration in % of the acceleration time
[acceleration time]
(ACC)
or
[acceleration time 2]
(AC2)
.
•
Can be set from 0 to (100% to
[Round Start ACC]
(tA1)
).
•
The parameter is accessible if
[Ramp Type]
(rPt)
is
[customer spec]
(CUS)
type.
tA3
[Begin Dec round]
1)
0 to 100%
10%
•
Rounding of the start of the deceleration in % of the deceleration time
[deceleration time]
(dEC)
or
[deceleration time 2]
(dE2)
.
•
Can be set between 0 and 100%
•
The parameter is accessible if
[Ramp Type]
(rPt)
is
[customer spec]
(CUS)
type.
tA4
[End Dec round]
1)
10%
•
Rounding of the end of the deceleration in % of the deceleration time
[deceleration time]
(dEC)
or
[deceleration time 2]
(dE2)
.
•
Can be set from 0 to (100% to
[Round DEC Start]
(tA3)
).
•
The parameter is accessible if
[Ramp Type]
(rPt)
is
[customer spec]
(CUS)
type.
Summary of Contents for ACOPOSinverter P84
Page 2: ......
Page 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Page 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Page 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Page 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Page 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Page 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...