Programming guidelines
ACOPOSinverter P84 User's Manual 2.10
227
Code
Name/Description
Setting range
Factory settings
brH2
[BRH b2]
0
Taking the brake feedback into account for the brake control sequence.
0
[0]
(0)
: The brake contact remains unconsidered.
1
[1]
(1)
: The brake contact is considered.
Use in the open and closed-loop control
•
If a logic input is assigned to the brake contact.
[BRH b2]
(brH2)
= 0: During the brake release sequence, the reference is unlocked after the end of the
[brake engage time]
(brt)
. During
the brake engaging sequence, the current switches to 0 in accordance with the ramp
[current ramp time]
(brr)
after the expiry of the
time
[brake engage time]
(bEt)
.
[BRH b2]
(brH2)
= 1: When the brakes are released, the reference is unlocked when the logic input changes to 1. On closing, in accordance
with
[current ramp time]
(brr)
, the current switches to 0 if the logic input changes to 0.
Movement command
Relay or
Logic output
Frequency
Logic input
Response
Frequency
blr
Torque current
[BRH_b2]
(brH2)
= 0
[BRH_b2]
(brH2)
= 1
Torque current
brH3
[BRH b3]
0
Only available in the closed control loop. Management of missing brake contact response, if assigned.
0
[0]
(0)
: During the brake engaging sequence, the brake contact must be opened before the end of the
[brake engaging current]
(bEt)
, or the
inverter will be locked in an A brake contact fault
brF
.
1
[1]
(1)
: During the brake engaging sequence, the brake contact must be opened before the end of the
[brake engaging current]
(bEt)
, or a
bCA
brake contact alarm will be triggered and zero speed will be maintained.
brH4
[BRH b4]
0
Only available in the closed control loop. Activation of the speed controller at zero when a motion occurs for which no command has been issued
(when measuring a speed over a fixed minimum threshold).
0
[0]
(0)
: No action if a movement occurs for which no command has been issued.
1
[1]
(1)
: If a movement occurs for which no command has been issued, the inverter shuts down to zero speed control without brake release
command and a bSA alarm is triggered.
brr
[Current ramp time]
0 to 5 s
0 s
Time of the ramp for the torque current (increase and decrease) for a current change that corresponds to the value
[I brake engaging upw.]
(Ibr)
.
Parameter that can be modified during operation or when stopped.
Summary of Contents for ACOPOSinverter P84
Page 2: ......
Page 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Page 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Page 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Page 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Page 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Page 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...