Installation guide
ACOPOSinverter P84 User's Manual 2.10
59
Model number
8I84T403700.01P-1
8I84T404500.01P-1
8I84T405500.01P-1
8I84T407500.01P-1
Input impedance
Voltage
30 kΩ
Current
242 Ω
Relay outputs
Quantity
2
Nominal voltage
30 VDC / 250 VAC
Switching capacity
Min.
3 mA for 24 VDC
Max.
With resistive load (cos φ = 1
and L/R = 0 ms)
2 A for 250 VAC or 30 VDC
With inductive load (cos φ = 0.4
and L/R = 7 ms)
1.5 A for 250 VAC or 30 VDC
Design
Relay 1
1 NO contact and 1 NC contact with a common point
Relay 2
1 NO contact
Response time (max.)
<7 ms ±0.5 ms
Electrical isolation
Output - ACOPOSinverter
Yes
Output - Output
No
Analog outputs
Quantity
1
Output
0 to 10 V or 0 to 20 mA
8)
Electrical isolation
Output - ACOPOSinverter
Yes
Output - Output
No
Max. load impedance
Voltage
470 Ω
Current
500 Ω
Update time
<2 ms ±0.5 ms
Resolution
10-bit
Operating conditions
Installation at elevations above sea
level
0 to 1000 m
Degree of protection per EN 60529
Upper part: IP21 and IP41
Lower part: IP54 (heat sink)
Ambient temperature
-10 to 50°C
Max. ambient temperature
Up to 60°C
Relative humidity per IEC 60068-2-3
5 to 95%, non-condensing
No dripping water
Maximum installation elevation
Up to 3000 m
9)
Max. pollution degree per IEC/EN
61800-5-1
2 (non-conductive pollution)
Environmental conditions per IEC
60721-3-3
Class 3C1 and 3S2
Operating position
Vertical mounting orientation ±10%
Environmental conditions
Temperature
Storage
-25 to 70°C
Vibration
Operation
3 to 13 Hz: 1.5 mm amplitude / 13 to 200 Hz: 1 g
Shock
Operation
15 g, 11 ms
Mechanical characteristics
Dimensions
Width
240 mm
320 mm
Height
550 mm
630 mm
Depth
266 mm
290 mm
Weight
37 kg
45 kg
Table 18: 8I84T403700.01P-1, 8I84T404500.01P-1, 8I84T405500.01P-1, 8I84T407500.01P-1 - Technical data
1)
Shield plate included in delivery
2)
For shielded motor cables
≤50 m → At a clock frequency of 2 to 2.5 kHz
≤25 m → At a clock frequency of 2.6 to 12 kHz
3)
For shielded motor cables
≤100 m → At a clock frequency of 2 to 2.5 kHz and at a clock frequency of 2.6 to 12 kHz
4)
For shielded motor cables
≤300 m → At a clock frequency of 2 to 2.5 kHz
≤200 m → At a clock frequency of 2.6 to 12 kHz
5)
These values are valid for the rated clock frequency.
6)
The min. resistance value is specified at a temperature of 20°C.
7)
1 logic input, configurable as a logic input or PTC sensor input using a switch. Input for max. 6 PTC sensors in series: Nominal value <1.5 kΩ, 3 kΩ trigger
resistance, 1.8 kΩ reset value, short-circuit proof <50 Ω
8)
The analog output is configurable as a logic output.
9)
From 1000 to 3000 m, current reduced by 1% per 100 m
Summary of Contents for ACOPOSinverter P84
Page 2: ......
Page 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Page 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Page 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Page 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Page 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Page 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...