Programming guidelines
156
ACOPOSinverter P84 User's Manual 2.10
Motor parameters that can be accessed in the
[expert]
mode
This includes:
•
Parameters that are calculated by the inverter during autotuning in write-protected mode. For example,
R1r, calculated stator resistance in cold condition.
•
Some of these calculated parameters can be replaced by other values, if necessary. For example, R1w,
measured stator resistance in cold condition.
If a parameter Xyw is changed by the user, the inverter uses it instead of the calculated parameter Xyr.
Induction motor
If an autotuning is running or if a parameter of the motor that the autotuning depends on is amended,
the parameters (
[Rated mot. volt.]
(UnS)
,
[Rated motor frequency]
(FrS)
,
[Rated motor current]
(nCr)
,
[Rated motor speed]
(nSP)
,
[Rated motor power]
(nPr)
), put Xyw back to their factory settings.
Code
Name/Description
rSM
[R measured stator]
Stator resistance in cold condition, calculated by the inverter, in read-only mode. Value in milliohms (mΩ) to 75 kW (100 hp), in hundredths of
a milliohms (mΩ/100) over 75 kW (100 hp).
IdM
[Calc. magnpower]
Magnetizing current in A, calculated by the inverter, in read-only mode.
LFM
[Calculated stray field]
Leakage inductance in mH, calculated by the inverter, in read-only mode.
trM
[T2r]
Rotor time constant in ms, calculated by the inverter, in read-only mode.
nSL
[NSLr]
Nominal slip in Hz, calculated by the inverter, in read-only mode.
To change the nominal slip, change the
[nominal motor speed]
(nSP)
(
see "Drive parameters (bFr - nSP)" on page 151
).
PPn
[Number of pole pairs]
Number of pole pairs, calculated by the inverter, in read-only mode.
rSA
[Cust stator resist.]
Cold state stator resistance (per winding), modifiable value. In milliohms (mΩ) to 75 kW (100 hp), in hundredths of a milliohms (mΩ/100) over 75
kW (100 hp). On the integrated display terminal: 0 to 9999 then 10.00 to 65.53 (10000 to 65536).
IdA
[Idw]
Magnetizing current in A, modifiable value.
LFA
[LFw]
Leakage inductance in mH, modifiable value.
trA
[Cust. rotor t const.]
Rotor time constant in ms, modifiable value.
Summary of Contents for ACOPOSinverter P84
Page 2: ......
Page 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Page 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...