Programming guidelines
190
ACOPOSinverter P84 User's Manual 2.10
2.8.10.8 Command channel for configuration [profile I/O] (IO)
Reference and command separate, as in the configuration
[separated]
(SEP)
The command channels
Cd1
and
Cd2
are independent of the reference channels
Fr1
,
Fr1b
and
Fr2
.
[Cmd channel 1]
[Cmd channel 2]
[Cmd switching]
I/O
[Profile]
Graphic display terminal
STOP
nO
YES
nO
LI
Forced local
CMD Movement in right direction
Movement in left direction
STOP
(Stop Key priority)
Legend:
Parameters: The black rectangle corresponds to the factory setting with the exception of
[Profile]
.
Information:
The operation "Forced local" is not active in the
[Profile I/O]
mode.
Commands
Cd1
,
Cd2
:
•
Terminals, graphic display terminal, integrated communication interface, communication card