Programming guidelines
ACOPOSinverter P84 User's Manual 2.10
231
2.8.11.14 "Speed reference" mode:
Hoist command
or lower
Reference
HSP
FrS
OSP
0
Frequency
HSP
Calculated limit
FrS
OSP
0
tOS
t
t
t
OSP: Adjustable frequency step for load measurement
tOS: Load measuring time
Two parameters are used to reduce the speed calculated by the inverter, for the ascending and descending di-
rections.