Programming guidelines
130
ACOPOSinverter P84 User's Manual 2.10
2.8.5.6 Parameters that can be modified during operation or when the motor is stopped.
Code
Name/Description
Setting range
Factory settings
ItH
[Mot. therm. current]
0.2 to 1.5 In
1)
According to in-
verter performance
Motor thermal protection current, to be set to the rated current indicated on the nameplate.
ACC
[Acceleration]
0.1 to 999.9 s
3 s
Time for the ramp-up from 0 to
[Rated motor frequency]
(FrS)
. Make sure that this value is compatible with the moment of inertia of the frequency
inverter load.
dEC
[Deceleration]
0.1 to 999.9 s
3 s
Time till deceleration of
[Rated motor frequency]
(FrS)
(
see "Overview of parameters [SIMPLE START] (SIM-)" on page 127
) to 0. Make sure
that this value is compatible with the moment of inertia of the frequency inverter load.
LSP
[Low speed]
0 to 599 Hz
0
Motor frequency with minimum reference value, setting from 0 to
[High frequency]
(HSP)
.
HSP
[High speed]
0 to 599 Hz
50 Hz
Motor frequency with maximum reference value, setting from
[Low frequency]
(LSP)
to
[Max. output freq.]
(tFr)
. The factory setting changes
to 60 Hz if
[Standard Motorfreq.]
(bFr)
=
[60 Hz NEMA]
(60)
.
1)
In is the same as the rated current specified in the installation instructions and on the nameplate of the inverter.
Summary of Contents for ACOPOSinverter P84
Page 2: ......
Page 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Page 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Page 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Page 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Page 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Page 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...