Installation guide
88
ACOPOSinverter P84 User's Manual 2.10
Bipolar frequency reference
Source ±10 V
Frequency reference by axis control
Setpoint
±10 V
Axis control
AI
1+
AI
1-
CO
M
0
V
Switch SW1
The switch of the logic input LI6 (SW1) allows the use of the LI6 input:
•
Either as a logic input by setting the switch to the right position (factory setting)
•
Or for the motor protection using PTC sensor by setting the switch to the left position
LI
6
Motor
C
O
M
SW2 switch
With SW2, the integrated terminating resistor for the external CAN bus (CAN H and CAN L) is switched on or off.
Voltage supply to the control unit by an external source
The control card can be supplied by an external source of +24 V.
24 V source
COM
COM
24 V
P24