Programming guidelines
ACOPOSinverter P84 User's Manual 2.10
171
Input and output parameters (continued)
Code
Name/Description
Factory settings
bSP
[Reference template]
[Standard]
(bSd)
bSd
[Standard]
(bSd)
Frequency
HSP
LSP
-100%
+100%
LSP
HSP
0%
Setpoint
At zero reference the frequency = LSP
bLS
[LSP limit]
(bLS)
Frequency
HSP
HSP
LSP
LSP
-100%
+100%
Setpoint
At reference = 0 with LSP the frequency = LSP
bnS
[Suppr LSP]
(bnS)
HSP
LSP
HSP
LSP
Frequency
-100%
+100%
Setpoint
0
At reference = 0 with LSP the frequency = 0
bnS0
[deadband 0]
(bnS0)
Frequency
HSP
LSP
-100%
+100%
0%
HSP
LSP
Setpoint
This process is identical to
[Default]
(bSd)
, but in the following cases
the frequency at reference = 0 is also = 0:
•
The signal is below the [min value], which in turn is greater
than 0 (example: 1 V on a 2 to 10 V input)
•
The signal is above the [min value], which in turn is greater
than 0the [max. value] (Example: 11 V on a 0 to 10 V input)
If "bidirectional" has been set for the input field, the process is identical
to
[Default]
(bSd)
.
This parameter defines how the speed reference is taken into account, for analog inputs and Pulse input only.
In the case of the PID regulator, this is the PID output reference. The limits are defined by the parameters
[low speed]
(LSP)
and
[high speed]
(HSP)
see "Parameters that can be modified during operation or when the motor is stopped." on page 130
Summary of Contents for ACOPOSinverter P84
Page 2: ......
Page 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Page 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Page 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Page 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Page 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Page 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...