Programming guidelines
ACOPOSinverter P84 User's Manual 2.10
195
As the graphic display terminal may be selected as the command and/or reference channel, its action modes can
be configured.
The parameters on this page can only be accessed on the graphic display terminal, and not on the integrated
display terminal.
Information:
•
The command and/or the reference of the operator terminal is only active when the command
and/or reference channels are also active via the terminal, with the exception of
[T/K]
(command
via the operator terminal), which has priority on these channels. By pressing the key
[T/K]
(com-
mand via the operator terminal), the control is transferred back to the selected channel again.
•
Command and reference via the display terminal are impossible if the latter is connected to
more than one inverter.
•
The functions JOG, preset frequencies and ± speed are only accessible if
[Profile]
(CHCF)
is
set to
[together]
(SIM)
.
•
The functions for the predefined PID reference are only accessible if
[Profile]
(CHCF)
is set to
[together]
(SIM),
or
[separated]
(SEP)
•
The function
[T/K]
(command via the operator terminal) is accessible, regardless of the setting
in the
[Profile]
(CHCF)
.
Name/Description
Factory settings
[F1 key assignment]
[No]
[No]
: Not active
[Jog]
: JOG step mode
[Prefix v2]
: By pressing a button, the inverter is preset with the second frequency
[2nd preset frequency]
(SP2)
. Press STOP to stop the frequency inverter.
[Prefix v3]
: By pressing a button, the inverter is preset with the third frequency
[3rd preset frequency]
(SP3)
. Press STOP to stop the frequency inverter.
[Ref PID 2]
: Provides a PID reference that is equal to the second pre-selected reference of the PID
[2nd preset PID ref.]
(rP2)
without a run command. Only
executable if
[channel ref.1]
(Fr1)
=
[HMI]
(LCC)
. Not functional with
[T/K]
.
[Ref PID3]
: Provides a PID reference that is equal to the third pre-selected reference of the PID
[3rd preset PID ref.]
(rP3)
without a run command. Only exe-
cutable if
[channel ref.1]
(Fr1)
=
[HMI]
(LCC)
. Not functional with
[T/K]
.
[+ speed]
: + speed; only executable if
[channel ref.2]
(Fr2)
=
[HMI]
(LCC)
. Press the key to control the inverter and increase the speed. Press STOP to stop
the frequency inverter.
[- speed]
: - speed; only executable if
[channel ref2]
(Fr2)
=
[HMI]
(LCC)
and if
[+ speed]
is assigned to another key. Press the key to control the inverter and
decrease the speed. Press STOP to stop the frequency inverter.
[T/K]
: Command via the terminal, takes priority over
[Cmd switching]
(CCS)
and
[Ref. 2 switching]
(rFC)
.
[F2 key assignment]
[No]
Identical to
[F1 key assign]
.
[F3 key assignment]
[No]
Identical to
[F1 key assign]
.
[F4 key assignment]
[No]
Identical to
[F1 key assign]
.
[HMI cmd.]
[Stop]
If the function
[T/K]
is associated with a key and is active, this parameter defines the behavior for the point in time at which the graphic display terminal or the
external operator terminal takes back the control.
[Stop]
: Stops the inverter (although the controlled direction of operation and reference of the previous channel are copied (to be taken into account on the next
RUN command)).
[Copy done]
: Does not stop the inverter (the controlled direction of operation and the reference of the previous channel are copied).
Summary of Contents for ACOPOSinverter P84
Page 2: ......
Page 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Page 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Page 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Page 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Page 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Page 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...