Programming guidelines
ACOPOSinverter P84 User's Manual 2.10
233
2.8.11.16 Rope slack
The "rope slack" function can be used to prevent starting up at high speed when a load has been set down ready
for lifting but the rope is still slack (as illustrated below).
Speed
OSP
Last
rStL
tOS
The described frequency level (parameter
OSP
) is used for measuring the load. As long as this has not reached
the adjustable threshold
rStL
, which corresponds with the weight of the load hook, the effective measuring cycle
(parameters
OSP
and
tOS
) is not triggered.
Via the menu
[INPUTS/ OUTPUTS]
(I-O-)
the display of the status "Slack rope" can be assigned to a logic output
or relay.