2.8.11.25 Menu and parameters that can be switched in multimotor mode
•
[SETTINGS]
(SEt-)
•
[DRIVE DATA]
(drC-)
•
[INPUTS/ OUTPUTS]
(I-O-)
•
[CONTROL]
(CtL-)
•
[APPLICATIONS-FCT.]
(FUn-)
with the exception of the function
[MULTIMOTOR CONFIG]
(only configure once)
•
[FAULT MANAGEMENT]
(FLt)
•
[USER MENU]
•
[USER CONF.]
: The name of the configuration specified by the user in the menu
[FACTORY SETTING]
(FCS-)
2.8.11.26 Menu and parameters that can be switched in multiconfiguration mode
As in multimotor mode, except for the motor parameters that are common to the three configurations:
•
Nominal current
•
Thermal current
•
Nominal voltage
•
Rated frequency
•
Nominal speed
•
Nominal power
•
IR compensation
•
Slip compensation
•
Type of thermal protection
•
Thermal state
•
The autotuning parameters and motor parameters that can be accessed in expert mode
•
Type of motor control
Note:
No other menus or parameters can be switched.