Programming guidelines
110
ACOPOSinverter P84 User's Manual 2.10
2.6.8 Programming: Example for setting a parameter
RDY
Term
+0.00 Hz
0 A
1 DRIVE MENU
1.1 SIMPLE START MENU
1.2 MONITORING
1.3 SETTINGS
Code
<<
>>
Quick
1.4 DRIVE DATA
1.5 INPUTS/OUTPUTS
RDY
Term
+0.00 Hz
0 A
1.3 SETTINGS
Ramp increment
Deceleration:
Acceleration 2:
Deceleration 2:
Acceleration:
9.67 s
12.58 s
13.45 s
9.51 s
01
Code
<<
>>
Quick
RDY
Term
+0.0 Hz
0.0 A
Startup
5
9
Max = 99.99
Min = 0.01
<<
>>
Quick
ENT
ESC
ENT
ESC
ENT
ESC
ENT
or
9.
5
1 s
Note:
•
To select a parameter
– Turn the navigation button to scroll in the vertical direction.
•
To change a parameter
– Scroll with the << and >> keys (F2 and F3) in the horizontal direction and select the point
to be changed (the selected point is white on a black background).
– Turn the navigation button to change the point.
•
To cancel the change:
– Press ESC
•
To save the modification:
– Press the navigation button (ESC).