Programming guidelines
268
ACOPOSinverter P84 User's Manual 2.10
2.8.11.22.1 Calculated stopping distance (remote stop) after deceleration limit switch
This function can be used to control the stopping of the moving part automatically once a preset distance has been
traveled after the slowdown limit switch.
On the basis of the rated linear speed and the speed estimated by the inverter when the slowdown limit switch is
tripped, the inverter will induce the stop at the configured distance.
This function is useful in applications where one shared limit switch (for violations) with manual restart is shared for
both directions. It will then only respond to ensure safety if the distance is exceeded. The stop limit switch retains
priority in respect of the function.
Depending on the parameter
[Deceleration ramp type]
(dSF)
, one of the following two modes of operation is
achieved:
Frequency
Slowdown
frequency
Frequency
Slowdown
frequency
A
A
B
B
Distance
[Deceleration type]
[Optimized]
=
(dsF)
(OPt)
A: Slowdown limit switch reached
B: Automatic stop at a distance
Distance
[Stop distance]
(Std)
[Deceleration type]
[Standard]
=
(dSF)
(Std)
Note:
•
If the deceleration ramp is modified while stopping at a distance is in progress, this distance
will not be observed.
•
If the direction is modified while stopping at a distance is in progress, this distance will not
be observed.
Danger!
ACCIDENTAL OPERATION OF DEVICE
•
Check that the parameters configured are consistent (in particular, you should check that the
required distance is possible).
•
This function does not replace the stop limit switch required for safety.
Failure to follow these instructions will result in death or serious injury.
Summary of Contents for ACOPOSinverter P84
Page 2: ......
Page 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Page 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Page 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Page 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Page 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Page 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...