Installation guide
ACOPOSinverter P84 User's Manual 2.10
29
1.3.4 Technical data
1.3.4.1 Electrical data
1.3.4.1.1 8I84T200037.01P-1, 8I84T200075.01P-1, 8I84T200150.01P-1
Model number
8I84T200037.01P-1
8I84T200075.01P-1
8I84T200150.01P-1
General information
Certifications
CE
Yes
KC
Yes
UL
cULus E225616
Power conversion equipment
Motor power
Listed on nameplate, 1-phase
-
0.37 kW
0.5 PS
0.75 kW
1 PS
Listed on nameplate, 3-phase
0.37 kW
0.5 PS
0.75 kW
1 PS
1.5 kW
2 PS
Mains connection
Mains input voltage, 1-phase
-
1x 200 VAC -15% to 240 VAC +10%
Mains input voltage, 3-phase
3x 200 VAC -15% to 240 VAC +10%
Frequency
50 to 60 Hz ±5%
Apparent power (at 240 VAC)
1.3 kVA
-
Apparent power (at 240 VAC), 1-phase
-
1.4 kVA
2.4 kVA
Apparent power (at 240 VAC), 3-phase
-
2.2 kVA
4 kVA
Max. assumed short circuit current (lsc)
(short circuit current at connection point)
5 kA
Max. mains current with optional mains choke
At 230 VAC
1.6 A
3.0 A
5.8 A
Mains current
At 200 VAC
3.5 A
-
At 200 VAC, 1-phase
-
6.9 A
12 A
At 200 VAC, 3-phase
-
6.1 A
11.3 A
At 240 VAC
3.1 A
-
At 240 VAC, 1-phase
-
5.8 A
9.9 A
At 240 VAC, 3-phase
-
5.3 A
9.6 A
Power dissipation at nominal load and nominal
clock frequency
46 W
66 W
101 W
Integrated EMC filter
Yes
1)
Line-conducted and radiated emissions
With integrated filter
Motor cable length per IEC/EN 61800-3
Cat. C1 environment 1 (public power system)
-
Motor cable length per IEC/EN 61800-3
Cat. C2 environment 1 (public power system)
≤10 m / ≤5 m
2)
Motor cable length per IEC/EN 61800-3
Cat. C3 environment 2 (industrial power system)
≤10 m / ≤5 m
2)
With add-on filter
8I0FT012.300-1
With add-on filter
Motor cable length per IEC/EN 61800-3
Cat. C1 environment 1 (public power system)
≤50 m / ≤20 m
3)
Motor cable length per IEC/EN 61800-3
Cat. C2 environment 1 (public power system)
≤100 m / ≤50 m
4)
Motor cable length per IEC/EN 61800-3
Cat. C3 environment 2 (industrial power system)
≤100 m / ≤50 m
4)
Motor connection
Derating of continuous output current depending on
ambient temperature
At nominal clock frequency (4 kHz or 2.5 kHz
with higher inverter power)
No derating (up to 50°C)
Other clock frequencies
The derating curves are included in the installation instructions, which
can be downloaded from the website (www.br-automation.com).
Derating of continuous output current depending on
installation elevation
Starting at 1000 m above sea level
1%, per 100 m
Max. continuous output current (In)
At 230 VAC, 1-phase
-
3 A
5)
4.8 A
5)
At 230 VAC, 3-phase
3 A
5)
4.8 A
5)
8 A
5)
Max. transient current for 60 s, 1-phase
-
4.5 A
7.2 A
Max. transient current for 60 s, 3-phase
4.5 A
7.2 A
12 A
Max. transient current for 2 s, 1-phase
-
4.9 A
7.9 A
Max. transient current for 2 s, 3-phase
4.9 A
7.9 A
13.2 A
Output frequency range
0.5 to 599 Hz
Nominal clock frequency
4 kHz
Table 10: 8I84T200037.01P-1, 8I84T200075.01P-1, 8I84T200150.01P-1 - Technical data
Summary of Contents for ACOPOSinverter P84
Page 2: ......
Page 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Page 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Page 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Page 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Page 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Page 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...