Accessories
370
ACOPOSinverter P84 User's Manual 2.10
Model number
8I0CT004.000-1
8I0CT010.000-1
8I0CT016.000-1
General information
Certification
CE
Yes
KC
Yes
Mains connection
Power loss
45 W
65 W
75 W
Inductance
10 mH
4 mH
2 mH
Nominal current
4 A
1)
10 A
1)
17 A
1)
Voltage drop
From 3 to 5% of the rated supply voltage. Higher values result in torque loss.
Saturation current
-
Operating conditions
Installation at elevations above sea level
0 to 1000 m
Protection
Choke
IP00
Terminals
IP20
Max. relative humidity
95%, non-condensing
No dripping water
Ambient temperature
0 to 45°C
Max. ambient temperature
Up to 55°C
2)
Maximum installation elevation
3000 m
3)
Environmental conditions
Temperature
Storage
-25 to 70°C
Mechanical characteristics
Weight
1.5 kg
3.0 kg
3.5 kg
General information
Conformity to standard
IEC 61800-5-1 (protection level 1 regarding overvoltages in the mains supply according to VDE 0160)
Table 23: 8I0CT004.000-1, 8I0CT010.000-1, 8I0CT016.000-1 - Technical data
1)
Max. current = 1.65 x rated current for 60 seconds.
2)
With current reduction of 2% per °C above 45°C.
3)
From 1000 to 3000 m, current reduced by 1% per 100 m
Model number
8I0CT030.000-1
8I0CT060.000-1
8I0CT100.000-1
8I0CT184.000-1
General information
Certification
CE
Yes
KC
Yes
Mains connection
Power loss
90 W
94 W
260 W
220 W
Inductance
1 mH
0.5 mH
0.3 mH
0.155 mH
Nominal current
30 A
1)
60 A
1)
100 A
1)
184 A
1)
Voltage drop
From 3 to 5% of the rated supply voltage. Higher values result in torque loss.
Saturation current
-
370 A
Operating conditions
Installation at elevations above sea
level
0 to 1000 m
Protection
Choke
IP00
Terminals
IP10
IP00
Max. relative humidity
95%, non-condensing
No dripping water
Ambient temperature
0 to 45°C
Max. ambient temperature
Up to 55°C
2)
Maximum installation elevation
3000 m
3)
Environmental conditions
Temperature
Storage
-25 to 70°C
Mechanical characteristics
Weight
6.0 kg
11.0 kg
16.0 kg
31.0 kg
General information
Conformity to standard
IEC 61800-5-1 (protection level 1 regarding overvoltages in the mains supply according to VDE 0160)
Table 24: 8I0CT030.000-1, 8I0CT060.000-1, 8I0CT100.000-1, 8I0CT184.000-1 - Technical data
1)
Max. current = 1.65 x rated current for 60 seconds.
2)
With current reduction of 2% per °C above 45°C.
3)
From 1000 to 3000 m, current reduced by 1% per 100 m
Summary of Contents for ACOPOSinverter P84
Page 2: ......
Page 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Page 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Page 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Page 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Page 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Page 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...