Integrated safety functions
ACOPOSinverter P84 User's Manual 2.10
353
3.5 Safety monitoring
Safety function "Power removal"
If the "power removal" input is active, the inverter prevents the output power bridge so that a torque is prevented
in the motor.
The output power bridge is redundantly blocked by a software and hardware channel.
If a fault in the hardware of the safety function "Power removal" is detected, the inverter locks the converter output
power bridge with the aid of the redundancy, even if the power removal input is not active.
If the "power removal" input is active, the power bridge is locked by the software and the status "Power Removal"
active (
PrA
) is displayed.
If the power removal is active and faulty, the inverter switches to the mode "detected error" (
PrF
).
Summary of Contents for ACOPOSinverter P84