background image

※Contact TDK-Lambda concerning items not mentioned or items which are not clear. 

CC15

CC15

CC15

CC15-

--

-xxxxSxx

xxxxSxx

xxxxSxx

xxxxSxx-

--

-E , CC30

E , CC30

E , CC30

E , CC30-

--

-xxxxSxxx

xxxxSxxx

xxxxSxxx

xxxxSxxx-

--

-E Series Instruction Manual

E Series Instruction Manual

E Series Instruction Manual

E Series Instruction Manual    

 

1. Standard Connection Method

1. Standard Connection Method

1. Standard Connection Method

1. Standard Connection Method    

The connection method shown in Figure 1. 

DC

Input

Load

+Vin

-Vin

+Vout

-Vout

PO
RC

ALM

Fuse

SW

 

Fig. 1    Connection Method 

 

 

When not using the Remote Control function, use it with either the RC terminal open or connected to the 

Vin terminal. 

 

When not using the Alarm function, use it with the ALM terminal in an open condition. 

 

Use the PO terminal for controling multiple unit operation (series, parallel operation etc.). 

          For single unit operation, use the PO terminal in an open condition. 

 

The converter is to be operated exclusively on DC input.    Use of AC input will cause damage. 

 

2. Block Diagram

2. Block Diagram

2. Block Diagram

2. Block Diagram    

The block diagram is shown in Figure 2. 

  

DRIVE

+Vin

-Vin

RC

Control circuit

Auxiliary power

DRIVE

+Vout

-Vout

OCP

Voltage

detection

OVP

LVP

+Vin

-Vin

PO

ALM

+Vout

+Vout

-Vout

Voltage detecyion

(Hysteresis type)

Delay circuit

(20ms

50ms)

 

Fig. 2    Block Diagram

Summary of Contents for CC15-xxxx-Sxx-E Series

Page 1: ...ot using the Remote Control function use it with either the RC terminal open or connected to the Vin terminal When not using the Alarm function use it with the ALM terminal in an open condition Use the PO terminal for controling multiple unit operation series parallel operation etc For single unit operation use the PO terminal in an open condition The converter is to be operated exclusively on DC ...

Page 2: ...Converter Type CC15 48xxSxx E CC30 48xxSxx E Fuse Capacity 1A 2A 3 2 Input Side External Capacitor This converter is equipped with a capacitor on the input side and does not need an external capacitor to be attached to the input terminal side when the length of the line connection from the DC power source is short less than 1 meter is estimated However when the line to the input terminal is long o...

Page 3: ...input voltage reverse polarity connection Damage may occur if reverse polarity voltage is applied to the input terminal When the possibility of the application of reverse polarity voltage exits attach an external protection circuit as shown in Figure 3 4 DC Input Vin Vin Fuse Fig 3 4 Reverse Connection Prevention Circuit 3 5 Output Side External Capacitor When connecting a pulse load to this conve...

Page 4: ...le voltmeter or oscilloscope used for measuring The TDK ripple noise measurement is made according to the method shown in Figure 3 6 Load Vout Vout Cout DC Input Vin Vin Oscilloscope Bw 100MHz 25mm R C 1 5m 50Ω Coaxial Cable JEITA attachment R 50Ω C 0 1μF 3 3V 5V output Cout 22μF 12V 15V output Cout 0 1μF Fig 3 6 Ripple Noise Voltage Measurement Circuit Caution when Adding External Capacitor Cout ...

Page 5: ... is ON If the RC terminal is set at H Level the output is OFF When the converter is in a latch stop condition because of a protection function after removing the abnormal factor use the Remote Control to turn the output OFF then turn ON after the lapse of 1 second minimum for recovery to occur Qrc Vin Vin R3 DC Input RC RC Control Signal R2 Qrc Vin Vin R3 R2 DC Input RC R1 RC Control Signal Fig 4 ...

Page 6: ...nnected together when an abnormality occurs and the alarm signal operates in 1 unit the other connected units can be stopped Converters having different output voltages can be connected This applies only to converters belonging to this series Use the ALM terminal at a maximum sink current of 10mA The maximum number of units to which the ALM terminal can be connected is 20 units 4 3 Simultaneous St...

Page 7: ...oved recovery can be achieved either by restarting the input power source or by using the remote control function 4 5 Over Voltage Protection These converters are equipped with a built in over voltage protection circuit When the output voltage becomes 115 145 of the rated voltage the over voltage protection circuit operates When the output current is less than 50 of the rated current depending on ...

Page 8: ... same type in series The maximum number of converters which can be operated in series is 2 When using series operation connect the Vin terminal Vin terminal PO terminal and ALM terminal of each converter to the same terminal of the other DC Input Vin Vin Vout Vout PO RC ALM Fuse SW Load Vin Vin Vout Vout PO RC ALM Fuse LED Fig 4 7 Example Series Operation Connection ...

Page 9: ...t the PO terminal and ALM terminal of each converter to the same terminal of the other As much as possible insure that the width length and material of the wiring used for connecting each converter to the load are identical There is the possibility that the current balance will collapse if there is a difference in the wiring from each respective converter to the load DC Input Vin Vin Vout Vout PO ...

Page 10: ...er Dip 260 10 sec Max Solder Iron 380 3 sec Max SMD Model Lead free solder high temperature reflow process conditions are shown in Figure 5 1 The number of times permitted for reflow is 1 time TP 225 Ty2 Ty1 部品表面温度 ハンダ付け時間 s A A B B C A A B B C 1 0 3 0 sec Ty1 150 10 Ty2 170 10 Ty1 Ty2 20 100sec 1 0 4 0 sec TP MAX 245 225 以上 20 40sec 1 0 5 0 sec Fig 5 1 Reflow Process Conditions for SMD Models 5 2...

Page 11: ...talling the converter on the board avoid having trace pattern etc in the slanted line area shown in Figure 5 3 because there is the possibility of an insulation defect occurring CC15 xxxxxSx E CC30 xxxxxSx E 38 2 29 6 33 5 38 2 34 7 1 75 1 75 34 7 1 75 1 75 Out line Out line Fig 5 2 Trace Pattern Prohibited Area ...